background image

28.09.2012

5

Freezer Metos Econo BD-600W

3.1 Construction

UPPER HINGE  

18 

EVAPORATOR 

BOTTOM HINGE 

19 

ASSISTANT CONDENSER 

SELF-CLOSING HINGE 

20 

RETURN AIR TUBE 

4 ADJUSTABLE 

FEET 

21  CABINET 

JUNCTION BOX 

22 

EVAPORATOR COVER SUBASSEMBLY 

6 CASTOR 

23  COMPRESSOR 

7 LOCK 

24  THERMOSTAT 

SAFTY COVER OF COMPREESOR UNIT 

25 

SWITCH 

CONTROL PANEL 

26 

CONDENSER FAN MOTOR 

10  UNIT INSTALLATION BOARD  

 

 

11  ANTI-DEW TUBE INSIDE OF FRAME 

 

 

12 DOOR 

 

 

13 GASKET 

 

 

14 CAPILLARY 

 

 

15  EVAPORATOR FIXED SUBASSEMBLY 

 

 

16 CONDENSER 

 

 

Summary of Contents for Econo BD-600W

Page 1: ...Installation and Operation Manual FREEZER Metos Econo BD 600W 28 09 2012 4249051...

Page 2: ...eliminary electrical checks 4 2 3 Start up 4 3 Use 4 3 1 Construction 5 3 2 temperature controller 6 3 2 1 Setting the set point desired temperature 6 3 2 2 Switching the device ON OFF 6 3 3 Defrostin...

Page 3: ...s Do not store food in direct contact with the structure Both the appliance s construction features and the condensing unit s capacity have been de signed to store only pre cooled products In all appl...

Page 4: ...n accordance with the manufacturer s instructions and following local regulations Never use sockets or plugs without earth connection The mains socket must be earthed The manufacturer declines all res...

Page 5: ...an appropriate one by qualified personnel Check that the plug is plugged into the socket 2 3 Start up After the above controls have been thoroughly completed the appliance may be started up Turn the...

Page 6: ...URN AIR TUBE 4 ADJUSTABLE FEET 21 CABINET 5 JUNCTION BOX 22 EVAPORATOR COVER SUBASSEMBLY 6 CASTOR 23 COMPRESSOR 7 LOCK 24 THERMOSTAT 8 SAFTY COVER OF COMPREESOR UNIT 25 SWITCH 9 CONTROL PANEL 26 CONDE...

Page 7: ...alue using UP or DOWN Press SET to confirm the new value 3 2 2 Switching the device ON OFF Press UP for more than 3s The control and defrost algorithms are now disabled and the instru ment displays th...

Page 8: ...is appliance requires little maintenance The user can do the following pro cedures The condenser has to be cleaned regularly Before cleaning switch off the appliance with the main switch and unplug th...

Page 9: ...5 Technical information BD 600W Volum 600 l Outer messurements WxDxH 740 x 870 x 2050 mm Temperature 18 C Current 230V 1 50Hz Energy consumption kW h 24h 4 36 Power 297 W Refrigerant R134a Amount 160...

Page 10: ...un congealed liquid Blocking of refrigeration pipe Failure of condenser fan Failure of condenser fan Reducing the frequency of opening door Much fat and dirt in condenser and filter Cleaning the conde...

Page 11: ......

Page 12: ......

Reviews: