Rev. 02 - 11/2022
64
# 4 = 32 C° 55% RH (IEC/EN 60335-2-89)
# 5 = 43 C° 40% RH (IEC/EN 60335-2-89)
# 4 = 30 C° 55% RH (EN 16825 / EN 17032)
# 5 = 40 C° 40% RH (EN 16825 / EN 17032)
TE
CHNICAL DATA
Serial number plate position
The data plate is positioned externally, on the side or back of the device, and internally in the motor compartment.
The rating plate provides important technical information: this is essential in case of device maintenance or repairs: we recom-
mend you do not remove, damage or modify the plate.
EN
Serial number plate details
1 Manufacturer
2 Serial number
3 Code
4 Model
5 Voltage
6 Current absorbed during operation
8 Absorbed power
9 Power of the defrosting resistance
10 Rated power of other resistances
11 Lamp power
12 Maximum and minimum pressure
13 Coolant, type and quantity
15 Insulation blowing gas
16 Year of manufacture
17 Climate class (#)