7
Auto Power Off
Auto Power Off is a battery saving feature that puts the meter into a sleep mode if
the Function/Range Switch has not changed position in the last 30 minutes. To
wake the meter turn it off and then on.
The Auto Power Off feature can be disabled to keep the meter from going to sleep.
This feature is useful when using the MIN MAX mode for extended periods. To
disable the Auto Power Off feature use the following procedure:
1.
Set the Function Switch to
OFF
.
2.
Press and hold the
MIN MAX
button while turning the Function Switch to the
desired function.
3.
Continue to press the
MIN MAX
button until the display finishes this
initialization period and the reading settles.
4.
Release the
MIN MAX
button. The Auto Power Off feature will remain disabled
until the meter is turned off and then on.
HOLD Measurements
The
HOLD
button causes the meter to capture and continuously display a
measurement reading. To use the
HOLD
feature make a measurement, and then,
after the reading has stabilized, momentarily press the
HOLD
button. You can
remove the test leads and the reading will remain on the display. Pressing the
HOLD
button again releases the display.
Backlight
Pressing the
L
button illuminates the display with a blue backlight. The backlight
will automatically turn off in about 60 seconds. Frequent use of the backlight will
decrease battery life.
Product Maintenance
Cleaning
To clean the meter, use a soft cloth moistened with water. To avoid damage to the
plastic components do not use benzene, alcohol, acetone, ether, paint thinner,
lacquer thinner, ketone or other solvents to clean the meter.
Troubleshooting
If the meter appears to operate improperly, check the following items first.
1.
Review the operating instructions to ensure the meter is being used properly.
2.
Inspect and test the continuity of the test leads.
3.
Make sure the battery is in good condition. The low battery symbol
B
appears
when the battery falls below the level where accuracy is guaranteed. Replace a
low-battery immediately.
4.
Check the condition of the fuses if the current ranges operate incorrectly.
Battery and Fuse Replacement
See Figure
-13-
XW
WARNING
To avoid electrical shock remove the test leads from both the
meter and the test circuit before accessing the battery or the
fuses.
Summary of Contents for 34XR
Page 1: ...34XR R Professional Digital ...
Page 2: ... MADE IN TAIWAN PATENTS PENDING metermantesttools com 5 6 3 4 1 2 ...
Page 14: ...12 4 3 2 1 5 4 3 2 1 5 1 2 V V ...
Page 16: ...14 2 1 8 3 4 5 4 7 5 6 4 7 5 6 A 3 A 2 1 8 ...
Page 17: ...15 3 4 6 5 2 1 5 3 4 6 6 7 2 1 7 ...
Page 18: ...16 6 2 8 1 3 5 4 1 7 4 5 6 2 9 3 ...
Page 19: ...17 4 11 1 3 2 2 4 K 3 1 5 10 ...
Page 20: ...18 3 2 1 4 12 2 4 2 13 ...
Page 21: ...19 ...