6
Measuring Frequency
See Figure
-11-
1.
Set the Function Switch to
Hz
.
2.
Connect the Test Leads: Red to
Hz
, Black to
COM
3.
Connect the Test Probes to the signal source.
4.
Read the display. The Meter will autorange for the best resolution.
Measuring Dutycycle
See Figure
-12-
1.
Set the Function Switch to
%
.
2.
Connect the Test Leads: Red to
%
, Black to
COM
3.
Connect the Test Probes to the signal source.
4.
Read the display. The Meter will autorange for the best resolution.
Additional Features
Input Test Lead Warning
The meter emits a continuous tone when a test lead is placed in the
µA
mA
or
10A
input jack and the Function/Range Switch is not set to a correct current position. (If
the meter is connected to a voltage source with leads connected for current, very
high current could result). All current ranges are protected by fast acting fuses.
True-rms Measurements
For ac measurements most DMMs average the ac input signal and display the
result as an estimated rms value. This average-responding method is accurate for
sinusoidal waveforms, but can be very inaccurate for distorted waveforms. To
ensure the most accurate measurements, always use a true-rms DMM when
measuring ac voltage or ac current on circuits for the following kinds of
applications:
•
Power Supplies - diodes
•
Controllers
•
Power Limiting - SCR or Triac
•
Starting - motors
•
Florescent Lighting - ballasts
•
Speed Control - motors
•
Pulsed Signals
•
Any non-sinusoidal ac waveform
MIN MAX Measurements
The MIN MAX function reads and updates the display to show the maximum or
minimum value measured after you press the
MIN MAX
button.
Pressing the
MIN MAX
button for less than 1 second will put the meter into a mode
of displaying the maximum, minimum, or actual readings. Each time the button is
pressed, the meter will cycle to the next display mode as shown in the table below.
Press the
MIN MAX
button for more than 2 seconds to exit
MIN MAX
.
Button
Display
Value Displayed
< 1 second
MAX
Maximum value after feature activated
< 1 second
MIN
Minimum value after feature activated
< 1 second
MIN MAX
(blinks)
Normal measurement, actual reading
> 2 seconds
Exit
MIN MAX
Normal measurement, actual reading
Summary of Contents for 34XR
Page 1: ...34XR R Professional Digital ...
Page 2: ... MADE IN TAIWAN PATENTS PENDING metermantesttools com 5 6 3 4 1 2 ...
Page 14: ...12 4 3 2 1 5 4 3 2 1 5 1 2 V V ...
Page 16: ...14 2 1 8 3 4 5 4 7 5 6 4 7 5 6 A 3 A 2 1 8 ...
Page 17: ...15 3 4 6 5 2 1 5 3 4 6 6 7 2 1 7 ...
Page 18: ...16 6 2 8 1 3 5 4 1 7 4 5 6 2 9 3 ...
Page 19: ...17 4 11 1 3 2 2 4 K 3 1 5 10 ...
Page 20: ...18 3 2 1 4 12 2 4 2 13 ...
Page 21: ...19 ...