Continue to remove the Contact Tips using the following technique:
Once satisfied, reassembly of the CG Spray from the point of the Contact Tip removal is a
reverse of the above procedure. All components must be cleaned in an appropriate de-
greasing agent and blow dried before replacing.
For complete disassembly instruction of the CG Spray Head please see Section 4.3.
Remove the Air Concentrator by pulling forward.
5
At this point the Spray Head will look as shown and the
Contact Tips will be accessible.
6
7
Using
a
suitable
spanner, remove the
Contact
Tips
and
check for damage and
clean / replace as
necessary.