Page
23
of
48
Preparing to Spray continued…
“CLICK!”
“CLICK!”
A
B
Ensure that the tension on the Pistol is off by pushing the lever
in the direction shown. Push the wire manually through the
Rear Wire Guides on the pistol until the wires exit the front of
the Pistol.
Push the conduits onto the Pistol. A “click” will signal that they
are on correctly. Then release the wire tension lever.
Connect the Conduits.
A “click” will confirm they have attached
correctly.
Turn the energiser on. Wait 10 seconds for the drive unit to
power up. Pull the Trigger on the Pistol to drive the wire
through the other end of the conduits. Allow approximately
150mm to protrude through the conduits.
150mm
Using a pair of side cutters, trim the wires flush to the Air
Cap Face. The wire ends
MUST NOT
touch each other or
the Air Cap.
OR
6
7
8
9
If using Drum Dispensers: Ensure there is a gap between the feed cones to
avoid a short circuit
(A).
Remove the lid of the drum and pull out the wire. Feed the wire end through
the top of the feed cone and place the cone on top of the drum.
Tighten up the 3 retaining screws located around the base of the cone
(B)
to secure the cone to drum.
Feed the wire over the Roller
(C)
and through the guide in
the black block
(D)
then into
the Wire Tube until 200mm
emerges from the other end.
Attach an absorbent strip for
wire lubricant
(E).
Apply approximately 5ml of
lubricant to each strip (x2).
Adjust the pulley arm
(F)
to
give a smooth flow of wire
from the pulley to the Drive
Unit. The wire can now be
fed into the Drive Unit as per
points 2
– 9.
“CLICK!”
“CLICK!”
C
D
E
F
Summary of Contents for ARC150-2310D
Page 1: ...Page 1 of 48 ssue 21 11 11 ...
Page 14: ...Page 14 of 48 SECTION 2 THE EQUIPMENT 2 1 System Configurations ...
Page 41: ...Page 41 of 48 SECTION 5 FAULT FINDING 5 1 Operational Troubleshooting ...
Page 43: ...Page 43 of 48 SECTION 6 ILLUSTRATED PARTS LIST 6 1 Main Components 6 2 CG Spray Head ...
Page 46: ...Page 46 of 48 SECTION 7 INFORMATION TABLES 7 1 Typical Performance Figures ...