G_EN_08
45
12.2.5 Resetting a failure.
If, on igniting the fireplace, after approximately 40 seconds of sparking no flame can be detected, the fireplace will
go into fail co
ndition. The error message “F
xx
” appears on the screen.
You can now reset the fireplace by pressing both scroll arrows simultaneously. Wait 3 minutes after resetting
before igniting the fireplace again. The fireplace cannot be reset more than five times within 24 hours.
If this occurs, you should contact a recognized installer in order to repair the defect.
12.2.6 Replacing batteries
When the battery symbol “
” blinks on the screen, the batteries need to be replaced. Replacing the batteries
is done as follows:
Remove the remote control’s rear cover by sliding it down a few millimetres (see figure 1) and then lifting it.
Install new batteries in the holder as shown in figure 2.
Reinstall the rear cover of the RF remote control by putting the notches A and B of the rear cover (figure 3) into
the corresponding notches of the housing (figure 2).
Slide the rear cover upward in order to interlock it.
After having replaced the batteries the time indication will have to be reset.
Do not throw away empty batteries, but turn them in as domestic chemical refuse.
As to Belgium, there are collection points at Bebat.