Metalac Bojler Praktik MB 100 Instructions For Installation, Use And Maintenance Manual Download Page 9

9

ENG

The water heaters with heat exchanger are connected to water supply 

in the same way like regular water heaters. Water heaters with heat 

exchanger are ment for connection to other energy sources (central-

ized heating system, solar heating and heat punps). Entrance point 

of heated media to the heat exchanger is marked with red, while exit 

is marked with blue. Water heating with electrical heater and heat 

exchanger could function contemporary or separately.

Water heaters with heat exchanger are not designed for central heat-

ing systems which fluid temperature exceeds 110°C.

Due water heating, water pressure in water heater increas up to safe-

ty valve set limit, and water drops come out the valve. The drip

can be piped to the drain by installing a catching unit just below the 

safety valve.In case the existing plumbing does not enable you to 

pipe the dripping water from the return safety valve into the drain, 

you can avoid the dripping by installing a 3-litre expansion tank on 

the inlet water pipe of the boiler.

Water may come out in drops from the exhaust  pipe of pressure re-

duction device i.e, safety valve, this pipe has to be open and posi-

tioned downwise, to prevent freezing of the water in the pipe.

By regular function of the safety valve it should be possible to re-

move limescale sediment as well as to check if it is bloacked. 

Safety valve is delivered with the water heater and the sheme shows 

how to install it.

At installation of a water heater and its connection to water supply, it 
is recomanded to use new set of hoses, old ones should not be used.

CONNECTION TO POVER SUPPLY

Electric accumulation water heater is connected to power supply by 

valid standards for electrical installations, with a plug cable 3x1,5 mm 

H05VV.

Before connecting power supply cable, unscrew the two screws and 

remove protection cap of the electric water heater. The electric water 

heater is not delivered with a device to cut off the power from the 

supply permanently. A separating element of all the poles from the 

supply should be included, according to local installation rules. Such 

separating means have to be included in the electrical installation.

Summary of Contents for Praktik MB 100

Page 1: ...NSTALLATION USEANDCAREOFWATERHEATERS STANDARDMB30 50 80lit STANDARDMB80H PRAKTIKMB50 80 100 120lit PRAKTIKMB50 80 100 120lit Inox PRAKTIKMBPK80 120lit PRAKTIKMBPK80 120lit Inox SLIMMB30 50 80lit SLIMMB30 50 80lit Inox ...

Page 2: ...2 ENG CONTENTS Technicalinformation 3 Installation 4 Connection to water supply 8 Connection to power supply 9 Use controlandmaintenaceofelectricalwaterheaters 10 Waste disposal 11 ...

Page 3: ...r heaters are made according to valid standards and tested and certified by authorized laboratory Product technical characteristics are given on the sticker Table with Characteristics between connec tion pipes Picture 1 shows design of the water heater with all parts 1 Housing 2 Polyurethaneinsulation 3 Heatingtank enamelled 4 Screw seal nut washer 5 Heaterwithseal 6 Flange 7 Flangesealingrubber 8...

Page 4: ...0 PraktikMB120 100 120 0 6 0 6 32 132 36 156 Enamelled Mg anode Enamelled Mg anode 2000 2000 230 230 350 435 Model Capacity litres Nominalpressure Mpa Weightwhenfullofwater kg Corrosion protection type Heater power W Voltage Time of water heating from 15 C to 75 C Praktik MB 50 INOX 50 0 6 18 68 INOX Mg anode 2000 230 150 Praktik MB 80 INOX 80 0 6 22 102 INOX Mg anode 2000 230 255 Praktik MB 100 I...

Page 5: ...lled Mg anode 2000 230 105 Slim MB 50 50 0 6 21 71 Enamelled Mg anode 2000 230 155 Slim MB 80 80 0 6 29 109 Enamelled Mg anode 2000 230 305 Model Capacity litres Nominalpressure Mpa Weightwhenfullofwater kg Corrosion protection type Heater power W Voltage Time of water heating from 15 C to 75 C Slim MB 30 INOX 30 0 6 12 42 INOX Mg anode 2000 230 105 Slim MB 50 INOX 50 0 6 16 66 INOX Mg anode 2000 ...

Page 6: ...5 81 480 110 390 116 B mm 0 mm L mm N mm 293 384 884 953 395 454 454 354 100 130 360 100 130 360 600 130 360 730 240 300 493 604 303 395 454 354 300 130 360 320 130 360 130 240 300 793 744 603 395 454 354 600 130 360 460 130 360 380 240 300 Model PRAKTIK Heatingfluid max pressure MPa Heatexchanger connectors Heatexchanger surface m2 Heatingfluid max temperature C Enameledwatertank MBPKL80 MBPKD80 ...

Page 7: ...g on the position of the thermoregulator and this models are designed to be mounted only on wall not ceiling so pipes are toward floor STANDARD MB 80 H A mm C mm E mm 1004 190 415 B mm 0 mm L mm 204 395 610 Left water heater MB 80 HL Right water heater MB 80 HD WALL SIDE VIEW ...

Page 8: ...ter from return safety valve should come out meaning the valve is working correctly Non return valve prevents tank to empty in case of pressure fall in water supply pipeline If regular water pressure in the pipeline is higher than 0 6 Mpa 6 bar a reduction valve has to be mounted on the cold water inlet connection An interlocking must not come between the safety valve and the wa ter heater as it w...

Page 9: ...ank on the inlet water pipe of the boiler Water may come out in drops from the exhaust pipe of pressure re duction device i e safety valve this pipe has to be open and posi tioned downwise to prevent freezing of the water in the pipe By regular function of the safety valve it should be possible to re move limescale sediment as well as to check if it is bloacked Safety valve is delivered with the w...

Page 10: ...ter heating the water heater should first be disconnected from power supply line protection cap on the bottom should be taken off and by turning plastic button directly on the thermoregulator water heating temperature can be set to be lower or higher within the range 20 to 70 5 C For water heater types with external regulation by simple turning the button desired water heating temperature can be s...

Page 11: ...nscrew the safety valve mounted on the cold water inlet and wait for water to go out After that the unscrew the nut of the heater counterflange take out the flange with the heater remove the limescale and replace Mg anode If you use chemical products for limescale removal they must not come into contact with Mg anode anode should be taken out Af terwards the tank should be rinsed and refilled with...

Page 12: ...Revision 24 11 2012 god MetalacBojler Ljubićska1 32300GornjiMilanovac Srbija T 38132717432 712818 F 38132770498 E bojler metalac com www metalac com ...