Metalac Bojler Praktik MB 100 Instructions For Installation, Use And Maintenance Manual Download Page 6

6

ENG

Connection and installation measures:

Model

STANDARD MB 30

PRKTIK MB 50

PRKTIK MB 120

SLIM MB 80

STANDARD MB 50

PRKTIK MB 80

SLIM MB 30

MB STANDARD 80 

PRKTIK MB 100

SLIM MB 50

A

(mm)

C

(mm)

E

(mm)

M

(mm)

504

591

1091

1135

190

192

192

182

415

81

480

110

480

110

390

116

704

811

535

190

192

182

415

81

480

110

390

116

1004

951

785

190

192

182

415

81

480

110

390

116

B

(mm)

0

(mm)

L

(mm)

N

(mm)

293

384

884

953

395

454

454

354

100

130-360

100

130-360

600

130-360

730

240-300

493

604

303

395

454

354

300

130-360

320

130-360

130

240-300

793

744

603

395

454

354

600

130-360

460

130-360

380

240-300

Model PRAKTIK

Heating fluid 

max. pressure (MPa)

Heat exchanger 

connectors

Heat exchanger 

surface (m2)

Heating fluid 

max. temperature (°C) 

Enameled water tank:                             

 MB PKL 80;  MB PKD 80;                                  

MB PKL 120;  MB PKD 120;

Stainless steel water tank:            

MB PKL 80 RFI;  MB PKD 80 FI;

                   

MB PKL 120 FI;  MB PKD 120 FI;

0.6

G¾"

G½"

 0.25

 0.3

90

Picture 2

NNU

NNM

QUO

OOTI

O

b

j

G½" (

G¾")

Summary of Contents for Praktik MB 100

Page 1: ...NSTALLATION USEANDCAREOFWATERHEATERS STANDARDMB30 50 80lit STANDARDMB80H PRAKTIKMB50 80 100 120lit PRAKTIKMB50 80 100 120lit Inox PRAKTIKMBPK80 120lit PRAKTIKMBPK80 120lit Inox SLIMMB30 50 80lit SLIMMB30 50 80lit Inox ...

Page 2: ...2 ENG CONTENTS Technicalinformation 3 Installation 4 Connection to water supply 8 Connection to power supply 9 Use controlandmaintenaceofelectricalwaterheaters 10 Waste disposal 11 ...

Page 3: ...r heaters are made according to valid standards and tested and certified by authorized laboratory Product technical characteristics are given on the sticker Table with Characteristics between connec tion pipes Picture 1 shows design of the water heater with all parts 1 Housing 2 Polyurethaneinsulation 3 Heatingtank enamelled 4 Screw seal nut washer 5 Heaterwithseal 6 Flange 7 Flangesealingrubber 8...

Page 4: ...0 PraktikMB120 100 120 0 6 0 6 32 132 36 156 Enamelled Mg anode Enamelled Mg anode 2000 2000 230 230 350 435 Model Capacity litres Nominalpressure Mpa Weightwhenfullofwater kg Corrosion protection type Heater power W Voltage Time of water heating from 15 C to 75 C Praktik MB 50 INOX 50 0 6 18 68 INOX Mg anode 2000 230 150 Praktik MB 80 INOX 80 0 6 22 102 INOX Mg anode 2000 230 255 Praktik MB 100 I...

Page 5: ...lled Mg anode 2000 230 105 Slim MB 50 50 0 6 21 71 Enamelled Mg anode 2000 230 155 Slim MB 80 80 0 6 29 109 Enamelled Mg anode 2000 230 305 Model Capacity litres Nominalpressure Mpa Weightwhenfullofwater kg Corrosion protection type Heater power W Voltage Time of water heating from 15 C to 75 C Slim MB 30 INOX 30 0 6 12 42 INOX Mg anode 2000 230 105 Slim MB 50 INOX 50 0 6 16 66 INOX Mg anode 2000 ...

Page 6: ...5 81 480 110 390 116 B mm 0 mm L mm N mm 293 384 884 953 395 454 454 354 100 130 360 100 130 360 600 130 360 730 240 300 493 604 303 395 454 354 300 130 360 320 130 360 130 240 300 793 744 603 395 454 354 600 130 360 460 130 360 380 240 300 Model PRAKTIK Heatingfluid max pressure MPa Heatexchanger connectors Heatexchanger surface m2 Heatingfluid max temperature C Enameledwatertank MBPKL80 MBPKD80 ...

Page 7: ...g on the position of the thermoregulator and this models are designed to be mounted only on wall not ceiling so pipes are toward floor STANDARD MB 80 H A mm C mm E mm 1004 190 415 B mm 0 mm L mm 204 395 610 Left water heater MB 80 HL Right water heater MB 80 HD WALL SIDE VIEW ...

Page 8: ...ter from return safety valve should come out meaning the valve is working correctly Non return valve prevents tank to empty in case of pressure fall in water supply pipeline If regular water pressure in the pipeline is higher than 0 6 Mpa 6 bar a reduction valve has to be mounted on the cold water inlet connection An interlocking must not come between the safety valve and the wa ter heater as it w...

Page 9: ...ank on the inlet water pipe of the boiler Water may come out in drops from the exhaust pipe of pressure re duction device i e safety valve this pipe has to be open and posi tioned downwise to prevent freezing of the water in the pipe By regular function of the safety valve it should be possible to re move limescale sediment as well as to check if it is bloacked Safety valve is delivered with the w...

Page 10: ...ter heating the water heater should first be disconnected from power supply line protection cap on the bottom should be taken off and by turning plastic button directly on the thermoregulator water heating temperature can be set to be lower or higher within the range 20 to 70 5 C For water heater types with external regulation by simple turning the button desired water heating temperature can be s...

Page 11: ...nscrew the safety valve mounted on the cold water inlet and wait for water to go out After that the unscrew the nut of the heater counterflange take out the flange with the heater remove the limescale and replace Mg anode If you use chemical products for limescale removal they must not come into contact with Mg anode anode should be taken out Af terwards the tank should be rinsed and refilled with...

Page 12: ...Revision 24 11 2012 god MetalacBojler Ljubićska1 32300GornjiMilanovac Srbija T 38132717432 712818 F 38132770498 E bojler metalac com www metalac com ...

Reviews: