TROUBLESHOOTING
Failure
Possible Cause
Corrective Action
Unit does not power
up.
Unit is not plugged in.
Plug in unit.
Input power circuit breaker is not on.
Reset input power circuit breaker.
The main power switch is not working.
Replace main power switch.
Temperature indicator
is on.
The internal temperature is too high.
Leave power on and let the fan cool the unit.
Output will continue when the unit has cooled.
Cooling fan is damaged.
Replace cooling fan.
Alarm indicator is on.
Input power voltage is too high or too low.
Meter input power voltage. This unit must be used
with input voltage that ranges from 230V AC plus
or minus 15%. 120V plus or minus 15% when
operating on 120V.
TIG arc does not start.
Remote foot pedal control is broken.
Replace remote control.
Work piece is painted or rusty.
Remove all paint and rust.
Ground clamp is connected where there is paint or
rust.
Remove all paint and rust so ground clamp is
connected to bare metal.
Ground clamp is not electrically connected to the
work piece.
Make certain the ground clamp is connected to
the work piece.
Wrong shielding gas.
Check to make certain you are using 100% Argon
shielding gas.
Main PC Board has failed.
Replace the Main PC Board.
HF PC Board has failed.
Replace the HF PC Board.
Stick amperage seems
low.
Remote control is installed.
Remove remote control.
Amperage is set too low.
Increase the amperage. See the Setting-Up
Equipment section.
There is no shielding
gas.
Shielding gas bottle is empty.
Fill the shielding gas bottle.
Shielding gas bottle supply valve is off.
Open valve on shielding gas bottle.
Gas flow rate on regulator is off or very low.
Adjust gas flow rate to 20 CFH.
Gas valve has failed.
Replace gas valve.
Main PC Board has failed.
Replace Main PC Board.
Cooling fan is not
working.
Cooling fan has failed.
Replace cooling fan.
Cooling fan connections have come loose.
Inspect cooling fan connections and repair.
There is no display on
the digital meters.
The adjustment potentiometer has failed.
Replace the adjustment potentiometer.
The adjustment potentiometer connections have
come loose.
Inspect the adjustment potentiometer connections
and repair.
Main PC Board has failed.
Replace Main PC Board.
For assistance, contact the Welder Help Line at 888-762-4045