Table 1 - Performance and Dimensional Data - Tubular Propeller Unit Heater

DIMENSIONS .XXX STANDARD UNITS
DIMENSIONS IN PARENTHESIS (XXX) MILLIMETERS

Figure 2 - Dimensional Drawing – Tubular Propeller Unit Heater

D4617C

Unit Size 

 

100 125 150 175 200 250 300 350 400

PERFORMANCE DATA† 

 

 

 

 

 

 

 

 

 

Input 

BTU/Hr. 

 

100,000 125,000 150,000 175,000 200,000 250,000 300,000 350,000 400,000

 

 

(kW) 

(29.3) (36.6) (43.9) (51.2) (58.6) (73.2) (87.8) (102.5) 

(117.1)

Output 

BTU/Hr. 

 

83,000  103,750 124,500 145,250 166,000 207,500 249,000 290,500 332,000

 

 

(kW) 

(24.3) (30.4) (36.4) (42.5) (48.6) (60.7) (72.9) (85.1) (97.2)

Thermal Effi 

ciency 

(%) 

83 83 83 83 83 83 83 83 83

Free Air Delivery - CFM 

1,600  

2,200  

2,400  

2,850  

3,200  

3,450  

5,000  

5,600  

5,800 

 

 

(cu. 

m/s) 

(0.756) (1.039) (1.133) (1.346) (1.511) (1.629) (2.361) (2.644) (2.738)

Air 

Temperature 

Rise 

°F 

47 42 47 46 47 54 45 47 51

   

         (°C) 

(26) 

(23) 

(26) 

(26) 

(26) 

(30) 

(24) 

(26) 

(28)

Full 

Load 

Amps 

at 

120V 

6.4 6.9 6.9 8.0 8.0 8.0 11.3 

13.5 

13.5

MOTOR DATA:   Motor HP (Qty) 

1/10 

1/4 

1/4 

1/3 

1/3 

1/3 

1/4 (2) 

1/3 (2) 

1/3 (2)

 

 

Motor 

kW 

(0.080) (0.19) (0.19) (0.25) (0.25) (0.25) (0.19) (0.25) (0.25)

 

 

Motor 

Type 

SP  PSC PSC PSC PSC PSC PSC PSC PSC

   

RPM 

1,050  

1,140  

1,140  

1,140  

1,140  

1,140  

1,140  

1,140  

1,140 

 

 

Amps 

115V 4.2 4.7 4.7 5.8 5.8 5.8 9.4 11.6 

11.6

DIMENSIONAL DATA - inches (mm) 

 

 

 

 

 

 

 

 

 

"A" Overall Height to Top of Flue 

33-3/4 

33-3/4 

33-3/4 

33-3/4 

33-3/4 

33-3/4 

34 

34 

34

 

 

 

(857) (857) (857) (857) (857) (857) (864) (864) (864)

"B" 

Jacket 

Width 

of 

Unit 

20-3/4 20-3/4 20-3/4 32-3/4 32-3/4 32-3/4 50-3/4 50-3/4 50-3/4

 

 

 

(527) (527) (527) (831) (831) (831) (1289) 

(1289) 

(1289)

"C" 

Width 

to 

CL 

Flue 

13-3/8 13-3/8 13-3/8 19-3/8 19-3/8 19-3/8 28-3/8 28-3/8 28-3/8

 

 

 

(340) (340) (340) (492) (492) (492) (721) (721) (721)

"D" Depth to Rear of Housing 

11 

11 

11 

11 

11 

11 

12-1/4 

12-1/4 

12-1/4

 

 

 

(279) (279) (279) (279) (279) (279) (311) (311) (311)

"E" 

Hanging 

Distance 

Width 

18-5/8 18-5/8 18-5/8 30-5/8 30-5/8 30-5/8 48-5/8 48-5/8 48-5/8

 

 

 

(473) (473) (473) (778) (778) (778) (1235) 

(1235) 

(1235)

"F" 

Discharge 

Opening 

Width 

18-3/4 18-3/4 18-3/4 30-3/4 30-3/4 30-3/4 48-3/4 48-3/4 48-3/4

 

 

 

(476) (476) (476) (781) (781) (781) (1238) 

(1238) 

(1238)

"G" 

Depth 

to 

CL 

Flue 

4-3/4 4-3/4 4-3/4 4-3/4 4-3/4 4-3/4 5-1/8 5-1/8 5-1/8

 

 

 

(121) (121) (121) (121) (121) (121) (130) (130) (130)

"L" 

Overall 

Unit 

Width 

25-1/4 25-1/4 25-1/4 37-1/4 37-1/4 37-1/4 55-1/4 55-1/4 55-1/4

 

 

 

(641) (641) (641) (946) (946) (946) (1403) 

(1403) 

(1403)

"M" 

 

Flue 

Size 

Diameter* 

in  5 5 5 5 5 5 6 6 6

   

                (mm) 

(127) 

(127) 

(127) 

(127) 

(127) 

(127) 

(152) 

(152) 

(152)

Fan Diameter - in (Qty) 

16 

16 

16 

18 

18 

18 

16 (2) 

18 (2) 

18 (2)

Gas 

Inlet, 

Natural 

Gas 

in 

1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4

Gas Inlet, LP Gas - in 

1/2 

1/2 

1/2 

1/2 

1/2 

1/2 OR 3/4 

1/2 OR 3/4 

1/2 OR 3/4 

1/2 OR 3/4

Approximate 

Unit 

Weight 

lb 

133 145 155 191 201 211 307 321 335

   

                (kg) 

(60) 

(66) 

(70) 

(87) 

(91) 

(96) 

(139) 

(145) 

(152)

Approximate 

Ship 

Weight 

lb  173 185 195 241 251 261 367 381 395

   

                 (kg) 

(78) 

(84) 

(88) 

(109) 

(114) 

(118) 

(166) 

(173) 

(179)

†  Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 610m). For unit installations in U.S.A. above 2,000 ft. (610m), the unit input must be fi eld derated 4% for each 

1,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223.1 (N.F.P.A. No. 54).

  For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (610m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (610 to 1372m), the unit must be fi eld derated 

to 90% of the normal altitude rating, and be so marked in accordance with the ETL certifi cation. See Table 6A for fi eld deration information.

*  Flue collar is factory supplied with unit; to be fi eld installed per included instructions.  LEGEND: SP= Shaded Pole, PSC= Permanent Split Capacitor

Summary of Contents for TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS

Page 1: ...t any problem that may be found RECEIVING INSTRUCTIONS Inspect shipment immediately when received to determine if any damage has occurred to the unit during shipment After the unit has been uncrated c...

Page 2: ...on Air 5 7 Proper Clearances 5 7 Suspension of Units 5 7 Heat Throw Data 6 Gas Piping 8 9 ELECTRICAL CONNECTIONS 10 11 12 VENTING 13 14 15 16 17 OPERATION Explanation of Controls and Operation 18 Main...

Page 3: ...t Start Up Sheet located in this manual Use only the fuel for which the heater is designed see rating plate Using LP gas in a heater that requires natural gas or vice versa will create risk of gas lea...

Page 4: ...9 279 311 311 311 E Hanging Distance Width 18 5 8 18 5 8 18 5 8 30 5 8 30 5 8 30 5 8 48 5 8 48 5 8 48 5 8 473 473 473 778 778 778 1235 1235 1235 F Discharge Opening Width 18 3 4 18 3 4 18 3 4 30 3 4 3...

Page 5: ...ve the floor must be equipped with an OSHA approved fan guard Refer to the latest edition of NFPA 88A Parking structures In Canada installation must be in accordance to the latest edition of CSA B149...

Page 6: ...NR NR 44 47 58 66 71 75 6 1 13 4 14 3 17 7 20 1 21 6 22 9 60 8 75 80 85 90 95 110 125 130 138 2 4 22 9 24 4 25 9 27 4 29 0 33 5 38 1 39 6 42 1 10 65 70 75 79 83 95 109 115 120 3 0 19 8 21 3 22 9 24 1...

Page 7: ...ere is a possibility of distortion or discoloration of adjacent materials Make certain that the lifting methods used to lift the heater and the method of suspension used in the field installation of t...

Page 8: ...vity Gas Nominal Iron Internal Length of Pipe Feet meters Pipe Size Diameter 10 20 30 40 50 60 70 80 90 100 125 150 175 200 Inch Inch 3 0 6 1 9 1 12 2 15 2 18 3 21 3 24 4 27 4 30 5 38 1 45 7 53 3 61 0...

Page 9: ...al Fuel Gas Code in Canada according to CSA B149 See Tables 1 3 for correct gas piping size If gas pressure is excessive on natural gas applications install a pressure regulating valve in the line ups...

Page 10: ...tical vibration free surface free from air currents and in accordance with the furnished instructions Mount the thermostat approximately 5 feet 1 5m above the floor in an area where it will be exposed...

Page 11: ...11 ELECTRICAL CONNECTIONS continued Figure 5d Tubular Units Equipped with Natural Gas and Propane LP Gas...

Page 12: ...12 ELECTRICAL CONNECTIONS continued Figure 5e Tubular Unit Sizes with Optional 2 Stage Ignition...

Page 13: ...operating the gas unit heater will result in the spillage of flue gas into the occupied space 9 Avoid installing units in areas under negative pressure due to large exhaust fans or air conditioning W...

Page 14: ...isance or hazard or could be detrimental to the operation of regulators relief valves or other equipment The vent pipe equivalent length must not exceed 50 feet 15 2m Equivalent length is the total le...

Page 15: ...r in the absence of local codes with current CSA B149 1 Installation Codes for Natural Gas Burning Appliances and Equipment or CSA B149 2 Installation Codes for Propane Gas Burning Appliances and Equi...

Page 16: ...16 Figure 8A Figure 8B VENTING continued D3620F D3619C...

Page 17: ...17 VENTING continued Figure 9A Figure 9B D3661F D3662D...

Page 18: ...motor is de energized 6 The fan operation is delayed 30 seconds once the thermostat is closed and continues operation for 30 seconds after the thermostat opens NOTICE The start up fan delay must not e...

Page 19: ...eaters must be field derated to 90 of the normal altitude rating and be so marked in accordance with ETL certification See Table 6A for field deration information Check the gas input rate as follows R...

Page 20: ...Refer to Installation Instruction section on Adjustments Gas Input Rate for adjusting the manifold pressure Manifold Pressure Inc WC PROPANE LP GAS NATURAL GAS Heating Value BTU Hr Altitude Feet 8 6...

Page 21: ...t openings 3 Clean heat exchanger Refer to Installation 4 Determine cause and repair accordingly 1 Inspect all gas piping and repair 2 Check to ensure gas test ports are seated 3 Clean heat exchanger...

Page 22: ...tat 1 Replace or tighten 2 Clean power ventor wheel 3 Realign power ventor wheel 1 Check and tighten wires on fan circuit 2 Test for 115v on terminal ACB Heat and L2 if voltage is present replace moto...

Page 23: ...heat If not present and all checks are normal replace 1 Check power ventor circuit per wiring diagram 2 Check motor voltage and amp draw to motor name plate replace if motor found defective 3 Check f...

Page 24: ...er 3 5 Amp fuse on circuit board 1 Common side of transformer grounded to chassis 2 Loose spark ignitor 1 Gas supply off or gas supply pressure too low 2 Flame sense rod contaminated or loose wire 3 G...

Page 25: ...supplied with your unit NOTICE The heater and vent system should be checked once a year by a qualified technician All Maintenance Service information should be recorded accordingly on the Inspection...

Page 26: ...ing halogenated hydrocarbons precipitated in the air d to any workmanship of the installer of the Product 3 This limited warranty is conditional upon a advising the installing contractor who in turn n...

Page 27: ...ICATION OF PARTS PROPELLER UNIT HEATERS Figure 13 Heat Exchanger Assembly Figure 14 Electrical Control Panel Figure 11 Propeller Parts Figure 12 Component Parts D4430 Fan Guard Fan Blade Hardware Hard...

Page 28: ...Venter Assembly 300 400 Unit Sizes Shown HOW TO ORDER REPLACEMENT PARTS Please send the following information to your local representative if further assistance is needed contact the manufacturer s cu...

Page 29: ...29 NOTES...

Page 30: ...30 NOTES...

Page 31: ...11 Supply Voltage SV 1 115 1 60 5 230 3 60 2 208 1 60 6 460 3 60 3 230 1 60 7 575 3 60 4 208 3 60 Z Other Note Supply Voltage SV 2 7 include field mounted step down transformer 12 Motor Type MT 1 Ope...

Page 32: ...s equipment unless you fully understand the controls GAS EQUIPMENT START UP GENERAL With power and gas off Make certain all packing has been removed Tighten all electrical terminals and connections Ch...

Reviews: