RETURN AIR BOx (SPC-1D, AC-RBF-3, SPC-3D):
Each includes filter grill with metal frame, permanent
filter, and 2 clamp bands. SPC-1D is for ESP-2430JV. AC-
RBF-3 is for ESP-3642JV and SPC-3D is for ESP-4860JV.
RETURN AIR DUCT (SPC-4,5, & 6)
: Flexible, 10 feet
long with round shape. SPC-4 (15" dia.) for ESP-2430JV.
SPC-5 (19" dia.) for ESP-3642JV and SPC-6 (24" dia.)
is for ESP-4860JV .
PLENUM ADAPTOR
: 9" round OR 10" x 10" square
metal component to attach plenum duct to fan coil unit.
Plenum Adaptor - 9" Round - AC-PAJ
Plenum Adaptor - 10" x 10" Square - AC-PAJSQ
PLENUM DUCT & COMPONENTS:
May be 9" round
sheet metal or 10" x 10" (O.D.) square, fiberboard duct
types as specified by the installing contractor. Above
layout is shown as an illustrative assembly reference only.
SUPPLY TUBING (SPC-25-100):
Flexible, insulated,
2" I.D. and 3-1/4" O.D. Each section is 100 feet long.
R6 SUPPLY TUBING (AC-ST6-75):
Flexible, R6 insulated,
2" I.D. and 5-3/8" O.D. Each section is 75 feet long.
R8 SUPPLY TUBING (AC-ST8-50):
Flexible, R8 insulated,
2" I.D. and 6-1/4" O.D. Each section is 50 feet long.
INSTALLATION KITS:
Contains a specified amount
of sound attenuating tubes, kwik-connects, terminator
plates (incl. spring clips & screws), winter supply air
shut-offs and a balancing orifice set to complete
installation of room outlets. Supplied in (2) [AC-IKLT-2]
and (5) [AC-IKLT-5] outlet boxed quantities.
PLENUM TAKE-OFF KIT:
Contains a specific amount
of plenum take-offs, gaskets and fasteners to complete
installation of room outlets. Take-offs available for round
sheet metal or square fiberboard duct as specified by
installing contractor. Supplied in (2) [AC-TKMR-2] and
(5) [AC-TKMR-5] outlet boxed quantities for round sheet
metal and (2) [AC-TKFS-2] and (5) [AC-TKFS-5] outlet
boxed quantities for square fiberboard.
KWIK CONNECT WALL ELBOW (AC-KCWE):
To allow
for wall terminations in 2" x 4" stud spaces.
PLIERS (SPC-72):
To assure full setting of all clips
(fasteners) in plenum take-off (not shown).
PLENUM hOLE CUTTER (SPC-71-10):
To cut 2" hole
in fiber board for plenum take-off installation (not shown).
FIGURE 1.1: AIR DISTRIBUTION SYSTEM COMPONENTS
Summary of Contents for SpacePak ESP-2430JV
Page 11: ...11 FIGURE 2 9 MODEL ESP JV STANDARD WIRING SChEMATIC ...
Page 12: ...FIGURE 2 10 SINGLE STAGE AIR CONDITIONING ONLY WIRING DIAGRAM 12 ...
Page 13: ...13 FIGURE 2 11 SINGLE STAGE AIR CONDITIONING WITh hW COIL WIRING DIAGRAM ...
Page 14: ...14 FIGURE 2 12 TWO STAGE hEAT PUMP AC WIRING DIAGRAM ...
Page 15: ...15 FIGURE 2 13 TWO STAGE hEAT PUMP AC WITh BACKUP BOILER hEAT WIRING DIAGRAM ...
Page 33: ...33 NOTES ...
Page 34: ...NOTES ...
Page 35: ...35 ...