39
Starting up the blind time switch
seconds, the blind is raised. Manual
and automatic operation of the blind is
blocked during this time and until the
wind speed drops again. The blind is
not automatically lowered after the
wind alarm is over.
All information about
assembly and
installation
of the blind control insert
and the blind time switch can be found
in the blind control insert manual.
When the mains voltage is connected,
the blind time switch is operational.
The time display flashes.
First perform a reset in order to delete
all data and restore the device to
factory settings:
1
Press the
[Mode]
and
[Set]
buttons
simultaneously for about
7 seconds, until all symbols in the
display go out.
The reset has been performed and the
default switching times are loaded (see
„Program memory and switching
times“, p. 32).
Now set the date and time (see
„Setting the date and time“, p. 43).
Irrespective of programmed switching
times, sun protection or twilight
functions, you can also operate the
blind by hand.
– Adjusting the slats: Press button
[
▲
]
or
[
▼
]
briefly (max. 1 sec.).
– Lowering: Press and hold button
[
▼
]
(for at least 1 sec.).
– Raising: Press and hold button
[
▲
]
(for at least 1 sec.).
– Stopping movement: Press button
[
▲
]
or
[
▲
]
.
The blind moves into position for
approx. 2 min or for a learned travel
time (see „Individual blind travel time“,
p. 36).
You can also operate the blind from an
extension unit (blind button or
additional blind time switch) when
using a blind control insert with
extension input (580699) (see blind
control insert manual). Manual or
automatic operation of the blind by the
blind time switch is blocked while the
extension unit is in operation or when a
wind alarm has been triggered.
Starting up the blind time
switch
Manual operation of the
blind