6 Installation
eikon e2s Installation and Operating Manual CE
50
6.1
Safe working during electrical installation
For your safety
Before starting work, familiarize yourself with the hazards described in '
Hazards and safety precautions
during installation
' on page 27.
Eligibility of personnel for the electrical installation
Only electricians qualified under the terms of EN 50110-1 and from an authorized service company are
permitted to perform work on electrical equipment.
Regulations for the electrical installation
Observe the following requirement to prevent hazards caused by faulty electrical connections:
The electrical supply must be connected in accordance with applicable local and national regulations
and regulations of the professional associations and of the relevant power supply company.
Personal protective equipment
Wear the personal protective equipment specified in the section '
Personal protective equipment
' on
page 37 of the '
For your safety
‘ chapter for the relevant tasks.
Live components
Risk of electric shock from live parts
When the appliance is not connected to an equipotential bonding system, there is a risk of electric
shock from touching live parts.
Make sure that any work on the electrical system is performed solely by a qualified electrician from an
authorized service company.
Make sure that the electrical connections are intact and connected securely before putting the
appliance into use.
Before preparing the appliance for use, make sure that the appliance, including all metallic accesso-
ries, is connected to an equipotential bonding system.
6.2
Planning the electrical installation
Meaning
It is crucial to the safe and reliable operation of the appliance that the electrical system is installed
carefully and correctly. All the rules and regulations listed here, and the described procedure, must be
strictly followed.
Rules for safe electrical installation of the appliances
Observe the following rules to prevent hazards caused by faulty electrical connections:
The electrical supply must be connected in accordance with applicable local regulations of the
professional associations and of the relevant power supply company.
The case of the appliance must be grounded in a suitable manner and connected to an equipotential
bonding system.
If two microwave combination ovens are installed in a stacking kit, both cases of the appliances and
the stacking kit itself must be grounded in a suitable manner and connected to an equipotential
bonding system.