11 Technical data
eikon e2s Installation and Operating Manual CE
108
11.1 Technical data
Dimensions and weights
Width
Including packaging
[in]
21.1
[mm]
535
Appliance without packaging
[in]
14.0
[mm]
356
Height
Including packaging
[in]
33.5
[mm]
850
Appliance ("Classic" exterior) without packaging
[in]
24.4
[mm]
620
Appliance ("Trend" exterior) without packaging
[in]
25.4
[mm]
644
Depth
Including packaging
[in]
35.3
[mm]
895
Appliance without packaging, door closed
[in]
25.0
[mm]
636
Weight
High Power version, including packaging
[lbs]
155
[kg]
70.4
High Power version, excluding packaging
[lbs]
134
[kg]
61.0
Standard Power version, including packaging
[lbs]
135
[kg]
61.1
Standard Power version, excluding packaging
[lbs]
114
[kg]
51.7
Safety clearances
Rear / right / left
[in]
0
[mm]
0
Top (for ventilation)
[in]
2
[mm]
50
Electrical connected load ratings
– High Power version
Electrical supply
1N~ 220-230V
50Hz
2N~ 380-400V
50Hz
1N~ 220V 60Hz
2~ 200V 50/60Hz
Connections used
L + N + E
L1 + L2 + N + E
L + N + E
2P + GND
Arrangement
Single Phase
Twin Phase
Single Phase
Two Pole
Rated power
consumption
[W]
6000
2500 + 3300
6000
6000
Rated current per phase [A]
32
16 / 32
32
32
Power output
Rated power output
convected heat
[W]
2200
2200
2200
2000
Rated power output
microwave (IEC 705)
100%
[W]
2000
2000
2000
2000
Rated power output
combination mode
[W]
2200 + 2000
2200 + 2000
2200 + 2000
2000 + 2000