Regulation of Air Supply to the Burner

The burners do not need a primary air regulator.

Minimum Regulation

Turn the gas valve to minimum.

Remove the knob and turn the regulator screw
(positioned either on the side of the top or inside the
shaft) clockwise until the flame becomes small but
regular.

N.B.:

 In the case of liquid gas, the regulation screw must

be fully screwed in (clockwise).

Make sure that, when the knob is turned rapidly high
to low, the flame does not go out.

In the event of a malfunction on appliances with the
security device (thermocouple) when the gas supply
is set at minimum, increase the minimum supply levels
using the regulator screw.

Once the adjustment has been made, apply sealing wax,
or a suitable substitute, to the old seals on the by-pass.

Table 1

Liquid Gas

Natural Gas

Burner

Diameter

(mm)

Thermal power

kW (p.c.s.*)

By-Pass

1/100

Nozzle

1/100

Flow*

g/h

Nozzle

1/100

Flow*

l/h

Nomin.

Ridot.

(mm)

(mm)

***

**

(mm)

Fast (R)

100

3,00

0,70

41

86

218

214

116

286

Semi Fast (S)

75

1,90

0,40

30

70

138

136

106

181

Auxiliary (A)

55

1,00

0,40

30

50

73

71

79

95

Supply

Pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20
35

37
25
45

20
17
25

**

At 15°C and 1013 mbar-dry gas

**

Propane P.C.S. = 50.37 MJ/kg.

***

Butane P.C.S. = 49.47 MJ/kg.
Natural P.C.S. = 37.78 MJ/m

3

Mains frequency and voltage of the electrical section
and characteristics of the gas section

Model

Gas section

Electric

section

Class Rated power kW (1)

Voltage

PC 640 GB

II2H3+

7,8 (567 gr/h-G30)

     (557 gr/h - G31)

230V~

50-60Hz

(1) The values in g/h refer to the capacities with liquid
gas (Butane, Propane).

Characteristic of the burners and nozzles

This appliance conforms with the following European
Economic Community directives:

-

73/23/

EEC

 of 19/02/73 (Low Voltage) and subsequent

modifications;

-

89/336/

EEC

 of 03/05/89 (Electromagnetic

Compatibility) and subsequent modifications;

-

90/396/

EEC

 of 29/06/90 (Gas) and subsequent

modifications;

-

93/68/

EEC

 of 22/07/93 and subsequent modifications.

S

S

A

R

PC 640 ... GB

Summary of Contents for PC 640 GB

Page 1: ...Built in cooking tables 60 Instructions for installation and use PC 640 GB ...

Page 2: ...ll the way in and turn in the counter clockwise direction to the High setting On those models fitted with an ignitor D the symbol is located near each knob To light a burner simply press the corresponding knob all the way in and then turn it in the counter clockwise direction to the High setting keeping it pressed in until the burner lights Caution If the burner accidently goes out turn off the ga...

Page 3: ...s come to a boil turn the knob to Low Practical Advice Burner ø Cookware diameter cm Fast R 24 26 Semi Fast S 16 20 Auxiliary A 10 14 Is there a problem The burner does not remain on when set to Low Check to make sure that The gas holes are not clogged There are no draughts near the cooking surface The minimum has been adjusted correctly see the section entitled Minimum Regulation The cookware is ...

Page 4: ...eaving the electric hobs on without cookware on top of them Closing the glass top if present while the gas burners are still hot Trying to install or repair the appliance without the assistance of qualified personnel The assistance of qualified personnel must be called upon in the following cases Installation in accordance with the manufacturer s instructions When in doubt about the operation of t...

Page 5: ...abinets provided the height does not exceed that of the hob For a correct installation of the cooking hob the following precautions must be followed a The hob may be located in a kitchen a kitonen diner or bed sitting room but not in a bathroom or shower room b The furniture standing next to the unit that is higher than the working boards must be placed at least 110mm from the edge of the board c ...

Page 6: ...ns on the rating plate located under the cooktop The earthing wire can be identified by its yellow green colour In the case of installation over a built in electric oven the electrical connections for the cooktop and oven should be independent not only for safety purposes but also to facilitate removal of one or both in the future Electrical Connection for Gas Cooktop Fit the supply cord with a st...

Page 7: ...w g h Nozzle 1 100 Flow l h Nomin Ridot mm mm mm Fast R 100 3 00 0 70 41 86 218 214 116 286 Semi Fast S 75 1 90 0 40 30 70 138 136 106 181 Auxiliary A 55 1 00 0 40 30 50 73 71 79 95 Supply Pressures Nominal mbar Minimum mbar Maximum mbar 28 30 20 35 37 25 45 20 17 25 At 15 C and 1013 mbar dry gas Propane P C S 50 37 MJ kg Butane P C S 49 47 MJ kg Natural P C S 37 78 MJ m3 Mains frequency and volta...

Page 8: ...viale Aristide Merloni 47 60044 Fabriano tel 0732 6611 telex 560196 fax 0732 662954 www Merloni com Piani incasso 60 comandi laterali 03 03 195029229 01 Xerox Business Services Docutech ...