10
3.
The 15 defined pre-programmes will be indicated as P0, P1, ....,P9, E1, E2, ...., E5 in the
display. Refer to the programme chart below and select one pre-programmed to suit the end
user.
4.
Press the MODE key once more. The DAY (F) LED will light up and indicate that a weekday
may be chosen.
5.
Press the SET/PAUSE key to choose one of the pre-programme profiles for the weekday.
1 is Monday, 2 is Tuesday,., 7 is Sunday.
6.
Press the MODE key once more, and the LED marked HOUR will light up. The correct hour
may be chosen.
7.
Press the MODE key once more. Now the LED marked MIN will light up, and the minutes can
be adjusted.
8.
After approximately 20 seconds the CREDASAVER returns to its normal operating mode and
all settings are stored.
5.
Cancellation of Setback Period
1.
A setback period can be cancelled by pressing the SET/PAUSE key when the CREDASAVER
is in its normal operating mode.
NOTE: - In the normal operating mode, none of the 5 red LEDs will be illuminated.
The present or first setback period will then be cancelled. To suspend the cancellation, the
SET/PAUSE key may be pressed once more.
CREDASAVER QUICK PROGRAMME GUIDE
PRESS ONCE
WAIT 20 SECONDS
PROG. SAVED
Fig. 6
Quick Setting Guide - Credasaver