9
100-300 mm
A
The door bracket must be securely fastened to the frame
or a structural support on the door.
Mounting position for Sectional Doors
1.Align the bracket on the centre line, measure down 100-
300 mm from the door top edge (use the door bracket
that best suits the situation)
.
2.Secure the bracket in this position, using the most
suitable variation of holes available.
Note: Only use 18mm Screws (item 9 in Hardware
Provided - Section 5).
FASTEN DOOR BRACKET
16
(1)
(2)
(3)
(4)
(5)
6mm MAX
(height of
bolt head)
HANG THE OPENER - X-RAIL
15b
The opener must be securely fastened to a sound
structural support above the opener.
1.Postion the operator as in the previous step. Check the
rail is centred over the door. Ensure the hanging brackets
are on the Operator end of the rail in a position as close
to the operator as possible (1).
2.If hanging the operator below the ceiling, bend the
hanging brackets provided, and secure to both the ceiling
(2) and the rail mounting screws (3).
3.If mounting directly onto the ceiling, drill appropriate
holes through the top of the rail. Use a minimum of 2
screws to fix to the ceiling. Screw the rail directly into a
structural support on the ceiling (4). Ensure screw head
height does not exceed 6mm (5) to avoid the screw head
interfering with the trolley movement.
4.Check the operator is securely centred over the door.
Remove the 50 mm spacer, and any other assembly
tools. Operate the door manually and check for
unrestricted operation.