Manual electrode welding operation
14
Choose the electrode type
•
Carry the step switch
1
in position
and adjust the
appropriate electrode type with the rotary knob.
4
The operating display
3
shows the settings.
Activate / deactivate the remote controller
•
Carry the step switch
1
in position
Turn right on rotary knob
4
: remote controller is activated
Turn left on rotary knob
4
: remote controller deactivated
If the remote controller active, the control lamp will glow on the
operating display
3
Display settings
•
Carry the step switch
1
in position
and adjust the
function with the rotary knob.
4
The display presents the
following information.
„A“
Display shows the welding current
„V“
Display shows the welding voltage
„A-V“ Display works in duplex operation and it shows the
welding current and the welding voltage alternate.
5.2
Hotstart settings for the welding current and the parameter
At first the height of the needed welding current is based upon the used electrode diameter. In
addition the material thickness of the base material, the material and the welding position have
essential influence on the needed current so that only approximate reference values will be
furnished on this position.
The following worths are the benchmark:
Electrodes- Ø (mm)
2,0
2,5
3,25
4,0
5,0
Current (A)
40-80
60-100
90-150
140-180
170-230
So that you obtain a good fusion penetration in the area of the initial weld, you can use the
hotstart function. During the hot start time, the welding current will be increased by a defined
percentage value over the value of the welding current. The accelerated fusing will be enabled
during the start phase therefore. The current drops to the value of the appointed welding
current after the expiration of the hotstart time. The hotstart current and hotstart time can be
changed, so you can ideal adjust the requirement.