INSTALLATION STEP 9
Connect Electric Power
TO AVOID SERIOUS PERSONAL INJURY
FROM ENTANGLEMENT, REMOVE ALL
ROPES CONNECTED TO THE GARAGE
DOOR BEFORE OPERATING OPENER.
TO AVOID DAMAGE TO GARAGE DOOR
AND OPENER, MAKE DOOR LOCKS
INOPERATIVE BEFORE CONNECTING
ELECTRIC POWER. USE A WOOD SCREW
OR NAIL TO HOLD THE LOCKS IN “OPEN”
(UNLOCKED) POSITION.
INSTALLATION AND WIRING MUST BE IN
COMPLIANCE WITH LOCAL ELECTRICAL AND
BUILDING CODES.
OPERATING AT OTHER THAN 120V 60Hz WILL
CAUSE OPENER MALFUNCTION AND DAMAGE.
PROCEDURE FOR PERMANENT WIRING (if required by local codes)
16
DISCONNECT THE POWER AT THE FUSE
BOX BEFORE PROCEEDING.
Refer to illustration. Make connection through the
22mm diameter hole in top of opener.
1. Remove opener cover screws and set cover
aside.
2. Remove attached 3-prong cord.
3. Connect black (line) wire to black wire on terminal
block; white (neutral) wire to white terminal wire;
ground wire to green ground screw.
CAUTION: BE SURE THAT THE UNIT IS
GROUNDED ACCORDING TO LOCAL CODE.
IMPORTANT NOTE: TO AVOID INSTALLATION
DIFFICULTIES, DO NOT RUN OPENER NOW.
Ground Tab
Green Ground
Screw
Ground Wire
Black
Wire
PERMANENT WIRING
CONNECTION
White
Wire
INSTALLATION STEP 8
Install Light and Lens
Install a 75 watt maximum light bulb in each socket.
Lights will turn ON and remain lit for 4-1/2 minutes
when power is connected. After 4-1/2 minutes, they
will turn OFF.
If bulb burns out prematurely due to vibration,
replace with a standard-neck “Garage Door
Opener”bulb.
INSTALL LENS: Slide lens into guides as shown.
Snap bottom tabs into lens slots.
Opener MUST be permanently wired or plugged into
a grounded 3-prong receptacle wired according to
local electrical codes. DO NOT use a 2-wire
adapter. DO NOT USE an extension cord.
Lens
75 Watt Max.
Light Bulb
Lens
Slot
Lens
Guide
RIGHT
WRONG