59
DSP5000 User Guide
2. Switch the power off. You have now set the test master.
3. Switch on the power supply to the slave speaker only while
continuously pressing the Previous key on the MSR
1L
65
4. Switch the power off. You have now set the test slave.
If you now turn both speakers on, they will come up in Test mode.
To get back to normal user mode:
1. Switch on the power to each speaker with the Clear key pressed
Controls
Test mode
Remote key
Logo
Input on
DSP5000
Control?
Channel
selected
CD
1L
D1
No
Left
Radio
1r
D1
No
Right
LP
2L
D2
No
Left
Tape 1
2r
D2
No
Right
Appendix 3 Calibrate mode
WARNING: THIS MODE MAY CHANGE THE RESPONSE OF YOUR
SPEAKER, AND SHOULD ONLY BE USED BY A QUALIFIED SERVICE
ENGINEER.
The process of calibration is carried out during production; it alters the
level of tweeter to compensate for the variability found in drive units. It
should therefore only be used if a drive unit needs to be replaced.
The calibration levels are noted on the back panel.
To enter Calibrate mode:
1. Switch on the power supply to the speaker while pressing the Repeat
key on the MSR
The calibration display looks like the Test mode display (see Appendix 2):
1L
65
This shows that you are in Calibrate mode and that the volume level is 65.
This mode operates like Test, but two menus are enabled.