3
Assembly
Connection to the power grid will be preferably through the rear plug.
In order to assemble the hand dryer complete the following steps:
Make four drill holes with an 8 mm (0,31”) diameter in the wall, using the provided template
(Figure 4).
Clean the dust away from the holes and insert the wall plugs.
Pass the electrical cabl
es from the power grid through the hole with the 22 mm (0,87”)
diameter which is situated above the device’s terminal strip (Figure 5).
Firmly screw the base of the device to the wall (Figure 6), ensuring that the 4 silent-blocks
are correctly placed between the base and the wall.
Connect the electrical cables to the hand dryer’s terminal strip. Connect the cables
corresponding to the two phases (N and L) and to earth in the corresponding sockets of the
terminal strip, as indicated by the engraved letters (Figure 7).
Figure 4.
Figure 5.
Figure 6.
Figure 7.
When making these connections contemplate means for
disconnecting from the power grid with a minimum contact separation
of at least 3 mm (0,12”) for all poles. These disconnection means
must be incorporated into the fixed installation.
The hand dryer must be installed against a solid surface only (wall,
partition, or similar).
Carefully place the casing on the base of the device. To do so place it
over the base with a slight incline from top to bottom, in such a way
that the tab in the casing correctly inserts into the corresponding slot
in the base (Figures 8 and nº 9).
Place the screws for fixing the casing to the base, fixing them tightly
using the special spanner provided (Figure 10).
Figure 8.
Figure 9.
Figure 10.
GB
Summary of Contents for M30A
Page 20: ...20 Machflow IR I 60 1 2 3 RUS 1 2 3...
Page 21: ...21 4 8 0 31 4 22 0 87 5 6 4 N L 7 4 5 6 7 3 0 12 8 9 10 8 9 10 RUS...
Page 22: ...22 11 U 12 400 15 80 13 14 11 12 13 14 RUS...
Page 23: ...23 120 150 4 72 5 9 600 700 2 36 2 76 15 2 3 14 60 15 RUS...
Page 24: ...24 2 3 I n 0 03 A RUS...
Page 25: ...25 1 RC9224008SMD 1 RC9213008SMD 1 RC9212008SMD 2 RC9111003SMD 3 RC9121011SMD RUS 1 2 3...
Page 38: ...38 Machflow IR I 60 1 2 3 UA 1 2 3...
Page 39: ...39 4 8 0 31 4 22 0 87 5 6 4 N L 7 UA 4 5 6 3 0 12 8 9 10 7 8 9 10...
Page 40: ...40 11 U 12 400 15 80 13 14 14 UA 11 12 13...
Page 41: ...41 120 150 4 72 5 9 600 700 2 36 2 76 15 2 3 14 60 UA 15...
Page 42: ...42 2 3 UA I n 0 03 A...
Page 43: ...43 1 RC9224008SMD 1 RC9213008SMD 1 RC9212008SMD 2 RC9111003SMD 3 RC9121011SMD UA 1 2 3...
Page 67: ...67...
Page 68: ...9 6 4 1 0 0 4 S MD 20 05 11...