OPERATION
36
Possible Cause
Horn
Monitor Display
Guardian
Activated and
Engine Power
Reduced
PCM Error
Steady Horn
Yes
Forced Idle
Battery charging high
or low
Steady Horn
Yes
Yes
Low Seawater
Pressure
Steady Horn
Yes
Yes
Low Oil Pressure
Steady Horn
Yes
Yes
Engine Overspeed
Steady Horn
Yes
No
Charge Temperature
Overheat
Steady Horn
Yes
Yes
MAP Sensor Error
Steady Horn
Yes
No
Oil Temperature High
Steady Horn
Yes
No
Coil Pack Failure
5 Beeps‑3 Sec.
Long
Yes
No
Fuel Injector Failure
5 Beeps‑3 Sec.
Long
Yes
No
Fuel Pump Failure
5 Beeps‑3 Sec.
Long
Yes
No
Idle Air Control
Failure
5 Beeps‑3 Sec.
Long
Yes
No
Guardian Envoked
3 Beeps‑1.5 Sec.
Long
Yes
No
Coolant Overheat
3 Beeps‑1.5 Sec.
Long
Yes
Yes
Knock Sensor
3 Beeps‑1.5 Sec.
Long
Yes
Yes
Charge Temperature
Sensor Failure
3 Beeps‑1.5 Sec.
Long
Yes
No
Oil Temperature
Sensor Failure
3 Beeps‑1.5 Sec.
Long
Yes
No
Cam Sensor
3 Beeps‑1.5 Sec.
Long
Yes
No
Oil Pressure Sensor
Failure
3 Beeps‑1.5 Sec.
Long
Yes
Yes
Summary of Contents for Racing Sterndrive 600SCi
Page 6: ...vi ...
Page 54: ...OPERATION 44 1 7 3 5 4 6 2 1 4 2 3 6 4 2 8 6 7820 3 7 ...
Page 61: ...OPERATION 51 ...