Section 6 - Storage
90-8M0099741
eng
JUNE 2015
Page 73
6. Pull the lever on the air pump (vertical) to lock the pump onto the fitting.
a -
Actuator fitting
b -
Green indicators
c -
Manual release valve
d -
Air pump
e -
Lever (locking)
7. Pump air into the system until both green indicators extend out of the actuator assembly.
8. Check to ensure water drains out of the distribution housing.
IMPORTANT: If water does not drain from the distribution housing when both green indicators are extended, remove the
blue plug on the distribution housing.
a -
Distribution housing water drain
b -
Blue plug
9. Check to ensure water drains out of the seawater pump housing.
IMPORTANT: If water does not drain from the seawater pump housing when both green indicators are extended, remove
the blue plugs on the seawater pump housing.
a -
Seawater pump housing water drain
b -
Blue plugs
8293
b
d
e
a
c
a
b
55101
a
b
56033