background image

Mercury Security Corporation, 

©

 2008

      BR20       Doc. 10107-0024  rev. 1.03  10/2008

  

                            

   Page 4

Information subject to change without notice.

11. Reader Verification:

The reader performs a self-test when power is first applied to the unit. If power-on test is successfully completed, the
reader will turn on both LEDs for approximately 1 second and sound the buzzer for 1 short beep. Then the reader is
ready for normal operation.

If further verification of the reader hardware is needed, the reader may be temporarily set to format 3. With this format
selected, the reader will read and verify standard ANSI track 2 encoded card. If no read error is detected, the green
LED will flash. Otherwise, the red LED will flash and the buzzer will sound two short beeps to indicate an error. The
LED input can be used to verify the LED function; and the buzzer input for the buzzer function. The reader will echo
a key press with a brief flash of both LEDs and a short beep of the buzzer. Reset to the required format for normal
operation after test.

12.  Maintenance:

The reader is designed to provide continuous service with minimal routine maintenance. However, contaminants (such
as magnetic oxides from badges and dirt) tend to accumulate on the read head. Without regular cleaning, these
contaminants will shorten the read head life and increase the probability of card read error. A maintenance schedule
should be developed base on the card reader environment  (dirty or clean) and the usage frequency (light traffic or heavy
traffic).  Extreme case may require daily cleaning.

Head cleaning may be done by using a disposable, pre-saturated magnetic head cleaning card. These cards are readily
obtainable from a number of sources (e.g. Clean Team Co., www.cleanteam.com, 800-888-8830; KIC Products,
www.kicproducts.com, 207-514-7030; System ID, www.systemid.com, 888-648-4452).

The reader exterior surface is covered with high strength polymer and polyester membrane. It may be cleaned with
a soft cloth and mild detergent if required.

13.  Specifications:

The reader is for use in low voltage, class 2 circuits only.

Power:

Voltage

5Volt Model: 5.8 Vdc (4.9 to 6.4 Vdc)
12Volt Model: 12 Vdc (10.2 to 13.8 Vdc)

Current

50mA (25mA typical.)

Data output:

Clock/data or data 1/0 pair
Timing

clock/data:

period 1mS
setup/hold time 400uS, clock pulse width 200uS typical

data 1/0:

period, 1mS for Wiegand data, 1mS for mag stripe data
pulse width 50uS typical

LED input:

1-wire mode

input not driven: LEDs 

OFF

input > 3.5Vdc: Red LED 

ON

input < 0.8Vdc: Green LED 

ON

2-wire mode

input < 0.8Vdc: Red LED 

ON

Buzzer/LED:

1-wire mode

input not driven or > 3.5Vdc:  buzzer 

OFF

input < 0.8Vdc: buzzer 

ON

2-wire mode

input < 0.8Vdc: Green LED 

ON

Mechanical:

Dimension

2.59" (66mm) W x 1.30" (33mm) H x 5.50" (140mm) L

Weight

11.3 oz. (320 g) nominal

Material

Case, Die cast aluminum, gray powder coat standard.
Mounting, stainless steel
Wall plate, 18 CRS, gray powder coat standard

Card:

75 bpi, ANSI X4.16, Track 2 standard, Speed 3 to 50 ips

Read Head:

1,000,000 passes typical.

Distance:

500'  (152m) with 18 AWG wires.

Environmental:

Temperature

-55 to +85 degrees C, storage
-40 to +75 degrees C, operating

Humidity

0-100% RHNC

Summary of Contents for BR20

Page 1: ...ACH CA 90815 1755 562 986 9105 FAX 562 986 9205 CAUTION DONOTDISCONNECT KEYPADWITHOUTDISENGAGING THECONNECTOR 3 Reader Wiring ThereaderhasaRJ 11modularjackforeasyfieldconnection Ashortpieceofpre terminatedcableissuppliedwith eachstandardreaderforfieldwiring Thepre terminatedcablehasnonstandardcolor Refertopinnumberifthepre terminated cable is not used Cable with wires of 24AWG or larger are recomm...

Page 2: ... the buzzer 2 wire control 0V turns on the green LED 6 Black SignalGround Power supply return DC ground 7 Grounding the Reader To avoid having ESD electrostatic discharge interfering with the operation of the reader the reader casing shall be grounded This can be accomplished by tying the mounting bracket to earth ground locally e g grounded conduit 8 DIP Switch Setting The DIP switch on the BR20 ...

Page 3: ... 99999 9 1 3 000 255 000 999 4 9 000000 065535 000000 999999 10 1 4 0000 0255 0000 4097 5 10 000000 065535 000000 999999 11 or more 1 5 00000 00255 00000 04097 6 11 000000 065535 000000 999999 AMC card 1 6 000000 000255 000000 004097 7 12 000000 065535 000000 999999 Format 6 26 bitWiegandcompatibleoutputfromstandardNorthernComputer32 bitmag stripecard Thelower 8 bits of the 16 bit facility code is...

Page 4: ...frequency lighttrafficorheavy traffic Extreme case may require daily cleaning Headcleaningmaybedonebyusingadisposable pre saturatedmagneticheadcleaningcard Thesecardsarereadily obtainable from a number of sources e g Clean Team Co www cleanteam com 800 888 8830 KIC Products www kicproducts com 207 514 7030 SystemID www systemid com 888 648 4452 The reader exterior surface is covered with high stre...

Page 5: ...ication Readerproductidentificationisprovidedon labels TheselabelshaveinformationonprogramID revision productID supply voltage and copyright notice These labels are located on the circuit board and the back of the reader Optional Wall Plate part WP10 Fitting Rigid Conduit to Junction Box 15 Reader Mounting Dimensions 0 99 25 DIMENSION INCH mm MOUNTING HOLE 2X Ø 18 4 5 2 60 66 3 30 84 1 30 33 WALL ...

Page 6: ...uthorize any agent or representative to make any other warranties or implied warranties and expressly excludes and disclaims all implied warranties of merchantability or fitness for aparticularpurpose Returnedunitsarerepairedorreplacedfromastockofreconditionedunits Returnsmustbeaccompaniedbyareturnauthorizationnumber RMA obtainedfrom customer service and prepaid postage and insurance Liability The...

Reviews: