The reader is rated to operate over an extended
temperature range and the electronics are conformal
coated against moisture.  If the reader is expected to
be exposed to weather, use the dielectric grease to
coat the field connections.  After field connection/
configuration is made, the grease is to be applied on
the DIP switch slides, keypad connection, and the
RJ-11 jack to seal out moisture.

Do not use sealant to seal reader case to the
wall

. Doing so will trap water in the reader and may

cause damage to the reader.

6. TTL Interface:

The TTL interface has the standard 5-wire interface widely used in the access control application. In addition, an input
to control the buzzer is provided. Cable with minimum of 24AWG wires should be used.

Pin #

Wire

Signal

Description

  1

Red

Vin

Power supply input, 5Vdc or 12Vdc, Model dependent

  2

Green

/Data (Mag) or

Reader data output

/Data 0 (Wieg)

  3

White

/Clock (Mag) or

Reader data output

/Data 1 (Wieg)

  4

Brown LED

LED input
1-wire control: 0V turns on the green LED

         5V turns on the red LED

2-wire control: 0V turns on the red LED

  5

Orange Buzzer/LED

Buzzer/LED input
1-wire control: 0V turns on the buzzer
2-wire control: 0V turns on the green LED

  6

Black

Signal Ground

Power supply return, DC ground

7. Grounding the Reader:

To avoid  having ESD (electrostatic discharge) interfering with the operation of the reader, the reader casing shall be
grounded. This can be accomplished by tying the mounting bracket to earth ground locally (e.g. grounded conduit).

8. DIP Switch Setting:

The DIP switch on the BR20 reader is used to select a preset format, the functions for the LED and buzzer, and the
output signal format, etc. The preset format determines how the card is interpreted. Refer to the format specification
for detail. The settings are for STANDARD models ONLY.  The BR20 does not support the tamper switch option.

MODULAR PLUG

1 (RED) +5 or +12Vdc

2 (GRN) DATA 0/DATA

3 (WHT) DATA 1/CLOCK

4 (BRN) LED

5 (ORG) BUZZER/LED

6 (BLK) GND

depends on model

FORMAT

SW -4

SW -3

SW -2

SW -1

OUTPUT

LED

BUZZER

TAMPER

0

ON

ON

ON

ON

DATA 1/DATA 0 1-W IRE LED

YES

NO

1

ON

ON

ON

OFF

CLOCK/DATA

1-W IRE LED

YES

NO

2

ON

ON

OFF

ON

CLOCK/DATA

1-W IRE LED

YES

YES

3

ON

ON

OFF

OFF

CLOCK/DATA

1-W IRE LED

YES

NO

4

ON

OFF

ON

ON

DATA 1/DATA 0 1-W IRE LED

YES

NO

5

ON

OFF

ON

OFF

DATA 1/DATA 0 1-W IRE LED

YES

NO

6

ON

OFF

OFF

ON

DATA 1/DATA 0 1-W IRE LED

YES

NO

7

ON

OFF

OFF

OFF

DATA 1/DATA 0 1-W IRE LED

YES

NO

12

OFF

OFF

ON

ON

CLOCK/DATA

2-W IRE LED

NO

NO

13

OFF

OFF

ON

OFF

DATA 1/DATA 0 2-W IRE LED

NO

NO

15

OFF

OFF

OFF

OFF

CLOCK/DATA

1-W IRE LED

YES

YES

Summary of Contents for BR20

Page 1: ...ACH CA 90815 1755 562 986 9105 FAX 562 986 9205 CAUTION DONOTDISCONNECT KEYPADWITHOUTDISENGAGING THECONNECTOR 3 Reader Wiring ThereaderhasaRJ 11modularjackforeasyfieldconnection Ashortpieceofpre terminatedcableissuppliedwith eachstandardreaderforfieldwiring Thepre terminatedcablehasnonstandardcolor Refertopinnumberifthepre terminated cable is not used Cable with wires of 24AWG or larger are recomm...

Page 2: ... the buzzer 2 wire control 0V turns on the green LED 6 Black SignalGround Power supply return DC ground 7 Grounding the Reader To avoid having ESD electrostatic discharge interfering with the operation of the reader the reader casing shall be grounded This can be accomplished by tying the mounting bracket to earth ground locally e g grounded conduit 8 DIP Switch Setting The DIP switch on the BR20 ...

Page 3: ... 99999 9 1 3 000 255 000 999 4 9 000000 065535 000000 999999 10 1 4 0000 0255 0000 4097 5 10 000000 065535 000000 999999 11 or more 1 5 00000 00255 00000 04097 6 11 000000 065535 000000 999999 AMC card 1 6 000000 000255 000000 004097 7 12 000000 065535 000000 999999 Format 6 26 bitWiegandcompatibleoutputfromstandardNorthernComputer32 bitmag stripecard Thelower 8 bits of the 16 bit facility code is...

Page 4: ...frequency lighttrafficorheavy traffic Extreme case may require daily cleaning Headcleaningmaybedonebyusingadisposable pre saturatedmagneticheadcleaningcard Thesecardsarereadily obtainable from a number of sources e g Clean Team Co www cleanteam com 800 888 8830 KIC Products www kicproducts com 207 514 7030 SystemID www systemid com 888 648 4452 The reader exterior surface is covered with high stre...

Page 5: ...ication Readerproductidentificationisprovidedon labels TheselabelshaveinformationonprogramID revision productID supply voltage and copyright notice These labels are located on the circuit board and the back of the reader Optional Wall Plate part WP10 Fitting Rigid Conduit to Junction Box 15 Reader Mounting Dimensions 0 99 25 DIMENSION INCH mm MOUNTING HOLE 2X Ø 18 4 5 2 60 66 3 30 84 1 30 33 WALL ...

Page 6: ...uthorize any agent or representative to make any other warranties or implied warranties and expressly excludes and disclaims all implied warranties of merchantability or fitness for aparticularpurpose Returnedunitsarerepairedorreplacedfromastockofreconditionedunits Returnsmustbeaccompaniedbyareturnauthorizationnumber RMA obtainedfrom customer service and prepaid postage and insurance Liability The...

Reviews: