Electrical System Overload Protection
If an electrical overload occurs, a fuse will blow or the circuit breaker will trip open. The cause must be found
and corrected before replacing fuse or resetting circuit breaker.
1
A circuit breaker provides protection for engine wiring harness and instrumentation power lead. Reset by
pushing RESET button IN.
NOTE: In an emergency, when engine must be operated and cause for high current draw cannot be located
and corrected, turn OFF or disconnect all accessories connected to engine and instrumentation wiring. Reset
circuit breaker. If breaker remains open, electrical overload has not been eliminated. Further checks must be
made on electrical system.
2
A 90 Amp fuse is located on the starter solenoid. This fuse is designed to protect the engine wiring harness
if an electrical overload occurs.
3
Three fuses are located on the port side of the engine. These fuses control various EFI circuits.
A
Fuel Pump Fuse - 15 Amp
B
ECM / Injector Fuse - 10 Amp
C
ECM / Battery Fuse - 15 Amp
4
A 20 amp fuse may be located in ignition switch “I” terminal lead to protect electrical system. Check for blown
fuse if key is turned to START and nothing happens (and circuit breaker is not tripped).
Summary of Contents for 350 MAG MPI Horizon
Page 1: ...Horizon Inboard Models 2001 Mercury Marine 90 861357002 101...
Page 13: ...11 CA961 THIS PAGE IS INTENTIONALLY BLANK...
Page 16: ...14 CC670 Courtesy of ABYC 2A 2B 3A 3B 1...
Page 30: ...28 CC882 70525 4 3A 3B 3C 71585 2 72852 1 74898 77001 2 3 77602 77498 1...
Page 43: ...41 THIS PAGE IS INTENTIONALLY BLANK...
Page 44: ...42 CH37 75540 2 76385 5 71419 7 70547 77631 2 2 2 4 8 7...
Page 46: ...44 CA514 1 3 70571 74767 74766 5 5 77631 3...
Page 48: ...46 CC1011 77629 3 70573 1...
Page 50: ...48 CH40 76360 76365 1 2 70573 2...
Page 52: ...50 CH42 3 4 71457 2 50946 1A 74941 1B 77597...
Page 54: ...52 CC886 3 4 74073 1 75637 7 2 75423...
Page 62: ...60 CC1017 77516 71515 77512 8 5 3 10 A 77638 3...