FEATURES AND CONTROLS
83
NOTE: There is a 10 second time frame to complete a helm
transfer. If the helm transfer is not completed, the action will be
cancelled and a double beep will sound. Pressing the
"TRANSFER" button again will re-initiate a helm transfer.
SYNC
1 LEVER
NEUTRAL
TROLL
THROTTLE
ONLY
DOCK
TRANSFER
+
-
22593
Synchronizing Helms Prior To Transfer
Pressing the "TRANSFER" button allows the boat operator 10
seconds to match up the control handle settings at the new helm
with the handle settings that are at the old (to be inactive) helm. If
the handles are not matched, the neutral lights will flash. The light
blinks faster as the handles are nearing match position. Once the
light stays on continuously, the handles are matched and the
button can be pressed again to complete the transfer. This
completes the transfer process, and gives control to the new
station. If the helm transfer is not completed within 10 seconds, the
action will be cancelled.
Warning System
WARNING HORN SIGNALS
When the key switch is turned to the "ON" position, the horn
(located on the command module harness) will turn on for a
moment as a test to indicate the horn is working.
The warning horn will emit either a continuous beep or intermittent
short beeps. This will alert the operator and help identify the
following listed situations. For visual display of the specific engine
functions and for additional engine data, refer to
SmartCraft
Product
information, following.
Warning Horn
Function
Sound
Description
Start up
Single beep
Normal system test
Summary of Contents for 200 VERADO
Page 4: ...iv ...