10. Specifications: 

** The interface is for use in low voltage, Class 2 Circuits only.  

The installation of this device must comply with all local fire and electronic codes. 

Primary power: 

12 Vdc ± 10%, 275 mA maximum 

Memory and  
Clock Backup: 

3 Volt Lithium, type BR2325, BR2330, or CR2330 

Ports: 

TB2 

 

2-wire RS-485:  9,600 to 115,200 bps, asynchronous 

Inputs: 

3 non-supervised, dedicated for cabinet tamper, low UPS battery and UPS power fault 
monitoring 

Cable requirements: 

Power: 

1 twisted pair, 18 AWG 

Ethernet: 

Cat 5 minimum 

RS-485: 

1 twisted pair with drain wire and shield, 120 ohm impedance, 24 AWG, 4,000 ft.  
(1,219 m) maximum 

Environmental: 

Temperature: 

-55 to +85 °C, storage 

0 to +50 °C, operating 

Humidity: 

5 to 95 % RHNC 

Mechanical: 

Dimension: 

5.8 in. (148 mm) W x 8.6 in. (218 mm) L x 1 in. (25 mm) H 

Weight: 

5.7 oz. (162 g) nominal, w/o terminal blocks 

Lantronix MICRO125 support:  

Lantronix part number: MO11AA003-01R or equivalent 

Standoff size: diameter .125 inch x 7/16 inch long.  Richco, Inc. part number LMSP-7-01, 3 pieces  

(not supplied) 

These specifications are subject to change without notice. 

Warranty 

Mercury Security warrants the product is free from defects in material and workmanship under normal use and 
service with proper maintenance for one year from the date of factory shipment.  Mercury Security assumes no 
responsibility for products damaged by improper handling or installation.  This warranty is limited to the repair 
or replacement of the defective unit. 

There are no expressed warranties other than set forth herein.  Mercury Security does not make, nor intends, 
nor  does  it  authorize  any  agent  or  representative  to  make  any  other  warranties,  or  implied  warranties,  and 
expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose. 

Returns  must  be  accompanied  by  a  Return  Material  Authorization  (RMA)  number  obtained  from  customer 
service, and prepaid postage and insurance. 

Liability

 

The Interface should only be used to control exits from areas where an alternative method for exit is available.  
This product is not intended for, nor is rated for operation in life-critical control applications.  Mercury Security 
is not liable under any circumstances for loss or damage caused by or partially caused by the misapplication or 
malfunction  of  the  product.    Mercury  Security's  liability  does  not  extend  beyond  the  purchase  price  of  the 
product. 

Summary of Contents for MS-ICS

Page 1: ...n ribbon cable up to two MS ACS are supported Standard Mercury remote serial I O panels may be connected to the external 2 wire RS 485 multi drop communication bus MS ICS J5 1 4 3 2 S1 ON D7 1 2 3 4 5 6 J8 TR TR GND TB2 4 1 BATTERY BR CR2330 REPLACE ANNUALLY GND TMP GND PFL GND BAT TB1 6 1 BT1 3V CR BR2330 S2 J4 J2 12VDC J1 1 1 75 44 55 6 11 155 19 8 58 218 01 J5 CONNECTION FOR LANTRONIX MICRO125 ...

Page 2: ...38 400 baud no encryption no flow control 3 Input Power Wiring The MS ACS requires 12 Vdc for input power and is connected to J2 Pins 1 and 2 are connected to ground and pin 3 is connected to 12 Vdc Observe POLARITY on 12 Vdc input J2 mates with the following housing and uses two crimp contacts Housing Molex 39 01 4030 Crimp contact Molex 39 00 0047 22 28 gauge 39 00 0039 18 24 gauge 4 Cabinet Tam...

Page 3: ...s 1 3 and 5 are turned ON for approximately 1 5 seconds after the hardware initialization has completed then the application code is initialized The amount of time the application takes to initialize depends on the size of the database about 3 seconds without a card database Each 10 000 cards will add about 3 seconds to the application initialization When LED s 1 through 4 flash at the same time d...

Page 4: ... seconds 7 When complete only LEDs 1 4 will flash for 8 seconds 8 The MS ICS board will reboot 8 seconds after LEDs 1 4 stop flashing no LEDs are on during this time 9 IT Security When installing the MS ICS it is important to ensure that it done in a secure manner Upon installation the user accounts to the web configuration page should be created with secure passwords and that all DIP switches are...

Page 5: ...tice Warranty Mercury Security warrants the product is free from defects in material and workmanship under normal use and service with proper maintenance for one year from the date of factory shipment Mercury Security assumes no responsibility for products damaged by improper handling or installation This warranty is limited to the repair or replacement of the defective unit There are no expressed...

Reviews: