Mercury Security Corporation © 2009
MR16in
DOC 10107-0010
REV 2.01
Page 5
7. Status LEDs:
Power-
up: All LED’s OFF
Initialization:
Once power is applied, initialization of the module begins
When initialization is completed, LEDs 1 through 16, CT, BA, A, and B are briefly sequenced
ON
then
OFF
.
Run time
: After the above sequence, the LEDs have the following meanings:
A LED
: Heartbeat and On-Line Status:
Off-line: 1 sec rate, 20%
ON
On-line:
Non-encrypted communication: 1 sec rate, 80%
ON
Encrypted communication:
.1 sec
ON
, .1 sec
OFF
, .1 sec
ON
, .1 sec
OFF
, .1 sec
ON
, .1 sec
OFF
, .1 sec
ON
, .3 sec
OFF
A LED Error Indication:
Waiting for application firmware to be downloaded: .1 sec
ON
, .1 sec
OFF
.
B LED
: SIO Communication Port Status:
Indicates communication activity on the SIO communication port
1 LED
: Input Status: 1
2 LED
: Input Status: 2
3 LED
: Input Status: 3
4 LED
: Input Status: 4
5 LED
: Input Status: 5
6 LED
: Input Status: 6
7 LED
: Input Status: 7
8 LED
: Input Status: 8
9 LED
: Input Status: 9
10 LED
: Input Status: 10
11 LED
: Input Status: 11
12 LED
: Input Status: 12
13 LED
: Input Status: 13
14 LED
: Input Status: 14
15 LED
: Input Status: 15
16 LED
: Input Status: 16
CT
: Cabinet Tamper
BA
: Power Fault
Input in the inactive state:
OFF (briefly flashes ON every 3 seconds)
Input in the active state:
ON (briefly flashes OFF every 3 seconds)
Input in a fault state:
Rapid Flash
LED K1
and
K2:
Illuminates when output relay RLY 1 (K1) or RLY 2 (K2) is energized.