8.  Specifications: 

The processor is for use in low voltage, class 2 circuit only. 

 

Primary power: 

 

12 to 24Vdc ±10%, 350mA maximum 

12Vdc @ 300mA nominal 

24Vdc @ 220mA nominal 

Outputs: 

 

 

2 outputs, Form-C, 5A @ 28Vdc, resistive 

Inputs: 

 

 

16 unsupervised/supervised, standard EOL: 1k/1k ohm, 1%, 1/4 watt 

2 unsupervised, dedicated for cabinet tamper and UPS fault monitoring 

Communication: 

 

RS-485, 2-wire.  9600, 19200, 38400, or 115200 bps 

 

Cable requirements: 

Power:   

 

18 AWG, 1 twisted pair 

RS-485: 

24AWG,  120  ohm  impedance,  twisted  pair  with  shield,  4,000'  (1,200m) 
maximum 

Alarm inputs: 

 

1 twisted pair, 30 ohms maximum 

Outputs: 

 

As required for the load 

 

Mechanical: 

Dimension: 

 

6" (152mm)W x 8" (203mm)L x 1" (25.4mm)H 

Weight:  

 

9 oz. (250 g)  nominal 

 

Environmental: 

Temperature: 

 

-55°C to +85°C, storage 

0°C to +70°C, operating 

Humidity: 

 

0% to 95% RHNC 

Warranty: 

Mercury  Security  Corporation  warrants  the  product  is  free  from  defects  in  material  and  workmanship  under  normal 
use  and  service  with  proper  maintenance  for  one  year  from  the  date  of  factory  shipment.    Mercury  Security 
Corporation  assumes  no  responsibility  for  products damaged  by  improper handling  or  installation.    This  warranty  is 
limited to the repair or replacement of the defective unit. 

There  are  no  expressed  warranties  other  than  set  forth  herein.    Mercury  Security  Corporation  does  not  make,  nor 
intends,  nor  does it authorize any  agent  or  representative  to  make  any  other  warranties, or  implied  warranties,  and 
expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose. 

Returned  units  are  repaired  or  replaced  from  a  stock  of  reconditioned  units.    Returns  must  be  accompanied  by  a 
return authorization number (RMA) obtained from customer service, and prepaid postage and insurance. 

Liability:

 

The Interface should only be used to control exits from areas where an alternative method for exit is available.  This 
product is not intended for, nor is rated for operation in life-critical control applications.  Mercury Security Corporation 
is  not  liable  under  any  circumstances  for  loss  or  damage  caused  by  or  partially  caused  by  the  misapplication  or 
malfunction of the product.  Mercury Security Corporation's liability does not extend beyond the purchase price of the 
product. 

Reviews: