1.  General: 

The LP1501 intelligent controller provides decision making, event reporting and database storage for the 
Mercury  hardware  platform.    Two  reader  interfaces  configured  as  paired  or  alternate  readers  provide 
control for one physical barrier. 

Host communication is via the on-board 10-BaseT/100Base-TX Ethernet port. 

 

Note:  For UL compliance, the Power Sourcing Equipment (PSE) such as a PoE or PoE+ enabled network 
switch and/or PoE or PoE+ power injectors must be UL Listed under UL294B. 

Reader port 1 can accommodate a reader that utilizes TTL (D1/D0, Clock/Data), F/2F, or 2-wire RS-485 
device signaling (for example an OSDP reader), also provides tri-state LED control, and buzzer control 
(one wire LED mode only).  This port can also utilize multiple 2-wire RS-485 multi-dropped devices, such 
as up to two OSDP readers or up to eight remote serial I/O devices. 

Reader port 2 can accommodate a reader that utilizes TTL (D1/D0, Clock/Data), or F/2F signaling, also 
provides tri-state LED control, and buzzer control (one wire LED mode only).  Two Form-C contact relay 
outputs may be used for door strike control or alarm signaling.  The relay contacts are rated at 2 A @ 30 
Vdc, dry contact configuration.  Two inputs are provided that may be used for monitoring the door contact, 
exit push button or alarm contact.  Input circuits can be configured as unsupervised or supervised.  The 
LP1501 requires Power over Ethernet (PoE or PoE+) or 12 Vdc for power.  The LP1501 may be mounted 
in a 3-gang switch box; a mounting plate is supplied with the unit, or may be mounted in an enclosure; the 
supplied mounting plate has mounting holes that match the MR50 mounting footprint. 

2.  LP1501 Hardware: 

 

LP1501 Layout 

 

 

TB1

TB2

TB3

1

1

1

TB

1

TB5

1

TB4

1

TB

5

7 6 5 4 3 2 1

J7

J7: TAMPER

SWITCH

CONNECTION

3

4

S1

2 1

DIP SWITCHES

J5

J6

K2

K1

12V

PoE

J3

Ø .125 [Ø3.175]

6 PL

STATUS LEDs

EARTH GND

2.55 [64.77]

2.55 [64.77]

5.40 [137.16]

.15 [3.81]

2.

35 [

59.

6

9

]

2.

75 [

69.

8

5

]

.20 [5.08]

J6: ETHERNET
      CONNECTOR

J3: PoE/12Vdc
      POWER SELECTOR
      JUMPER

J5: Micro

USB JACK

J8: microSD CARD

(back side)

ON

V

|

|

|

|

|

|

This device complies with part 15 of the FCC Rules.  Operation 
is subject to the following two conditions: (1) This device may 
not  cause  harmful  interference,  and  (2)  this  device  must 
accept any interference received, including interference that 
may cause undesired operation. 

Summary of Contents for LP1501

Page 1: ...TTL D1 D0 Clock Data or F 2F signaling also provides tri state LED control and buzzer control one wire LED mode only Two Form C contact relay outputs may be used for door strike control or alarm signaling The relay contacts are rated at 2 A 30 Vdc dry contact configuration Two inputs are provided that may be used for monitoring the door contact exit push button or alarm contact Input circuits can ...

Page 2: ...2 GND Auxiliary Power Output Ground TB4 3 VIN Input Power 12 Vdc from local power supply TB4 4 GND Input Power Ground TB5 1 NO Relay K1 Normally Open Contact TB5 2 1 C Relay K1 Common Contact TB5 3 NC Relay K1 Normally Closed Contact TB5 4 NO Relay K2 Normally Open Contact TB5 5 2 C Relay K2 Common Contact TB5 6 NC Relay K2 Normally Closed Contact Note 1 Terms A B are from the RS 485 standard Jump...

Page 3: ...unication address 0 Alternate Host Port Disabled 4 Bulk Erase Configuration Memory The bulk erase function can be used for the following purposes Erase all configuration and cardholder database sanitize board Update OEM default parameters after OEM code has been changed Recover from database corruption causing LP1501 board to continuously reboot If clearing the memory does not correct the initiali...

Page 4: ...ote serial I O devices using MSP1 protocol or up to two OSDP devices If two OSDP devices are used reader port 2 will not support a third reader If only one OSDP device is configured then reader port 2 is available for a second reader The maximum cable length is 2000 ft 610 m Do not terminate any RS 485 devices connected to reader port 1 When powering remote device s from the LP1501 be cautious not...

Page 5: ...AL I O MODULE MR16in MR16out FOR EXAMPLE MR62e MR50 MR52 GND GND 12 Vdc TR TR MR62e FOR EXAMPLE MR50 MR16out MR16in MR52 GND TR 12 Vdc GND TR TR TR FIRST READER PORT REFER TO THE APPROPRIATE REMOTE SERIAL I O DEVICE INSTALLATION MANUAL FOR ADDRESS AND BAUD RATE SETTINGS DO NOT TERMINATE ANY OF THE DEVICES ON THE RS 485 MULTI DROP COMMUNICATION BUS EACH REMOTE SERIAL I O DEVICE MUST BE CONFIGURED W...

Page 6: ... a Common pole C a Normally Open pole NO and a Normally Closed pole NC When you are controlling the delivery of power to the door strike the Normally Open and Common poles are used When momentarily removing power to unlock the door as with a mag lock the Normally Closed and Common poles are used Check with local building codes for proper egress door installation Door lock mechanisms can generate E...

Page 7: ...ne 80 ON 2 Host Communication Activity 3 Readers combined Clock Data or D1 D0 Mode Flashes when Data is Received Either Input RS 485 Mode Flashes when Transmitting Data F 2F Mode Flashes when Data Acknowledgment is Received 4 Input IN1 Status OFF Inactive ON Active Flash Fault See Note 1 5 Input IN2 Status OFF Inactive ON Active Flash Fault See Note 1 6 Cabinet Tamper 7 Reserved for Future Use D9 ...

Page 8: ...nication Ethernet 10 BaseT 100Base TX and Micro USB port 2 0 with optional adapter pluggable model USB2 OTGE100 Inputs Two unsupervised supervised Programmable End of Line resistors 1k 1k ohm 1 watt standard One unsupervised input dedicated for cabinet tamper Outputs Two relays Form C contacts 2 A 30 Vdc resistive Reader Interface Power 12 Vdc 10 PoE PoE or local power supply 300 mA maximum Data I...

Page 9: ...Levels Feature Level Standby Power I Endurance IV Line Security I Destructive Attack I These specifications are subject to change without notice 14 Additional Mounting Information Sources for the optional items shown below 3 gang stainless steel blank cover Available from Leviton part number 84033 40 Graybar part number 88158404 Magnetic switch set G R I part number 505 FIELD WIRING LP1501 WITH IN...

Page 10: ...ied warranties and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose Returns must be accompanied by a Return Material Authorization RMA number obtained from customer service and prepaid postage and insurance Liability The Interface should only be used to control exits from areas where an alternative method for exit is available This prod...