Section 5 - Maintenance
90-864839070 AUGUST 2007
Page 113
5. Insert a small wire (repeatedly) to ensure speedometer pitot tube, trim tab cavity vent
hole, and trim tab cavity drain passage are unobstructed and drained.
8583
b
a
c
Typical Bravo drive unit
a -
Speedometer pilot tube
b -
Anode cavity vent hole
c -
Anode cavity drain passage
6. Crank engine over slightly with starter motor to purge any water trapped in seawater
pickup pump. DO NOT ALLOW ENGINE TO START
7. Store boat with sterndrive unit in full DOWN/IN position.
Flushing the Power Package
Your boat could come equipped with a combination of any of three different types of water
pickups: through the hull, through the transom, and through the sterndrive. The flushing
procedures for these systems are separated into two categories: sterndrive water pickups
and alternative water pickups. Consult your authorized Mercury MerCruiser dealer for
further explanation.
IMPORTANT: Bravo models equipped with closed cooling require dual water pickups and
must be equipped with a through‑hull or through‑transom pickup in addition to the
sterndrive water inlets.
FLUSHING ATTACHMENTS
a
b
c
21514
21515
a
b
Flushing attachments for dual water pickup
Flushing attachments for side water pickup
a -
Flushing device
b -
Hose attachment
c -
Dual water pickup flush gearcase
seal kit
Summary of Contents for 8.1 MAG
Page 46: ...Section 2 Getting to Know Your Power Package Notes Page 38 90 864839070 AUGUST 2007 ...
Page 62: ...Section 3 On The Water Notes Page 54 90 864839070 AUGUST 2007 ...
Page 68: ...Section 4 Specifications Notes Page 60 90 864839070 AUGUST 2007 ...
Page 130: ...Section 5 Maintenance Notes Page 122 90 864839070 AUGUST 2007 ...
Page 148: ...Section 7 Troubleshooting Notes Page 140 90 864839070 AUGUST 2007 ...