Specification 

Number Pressure Switch Mk.

Contact Position

Low 

Pressure

Hi-Vac.

Intermediate 

Pressure

High 

Pressure 

Lo-Vac.

-4122

-4129

-4132

-4123

“A”

“B”

“A”

“B”

“A”

“B”

“A”

“B”

ON

ON

OFF

OFF

ON

OFF

OFF

ON

OFF

ON

ON 

OFF

OFF

OFF

ON 

ON

OFF

OFF

ON

ON

OFF

ON

ON

OFF

Two-Stage Pressure Controls, Series D-400 Ranges and Differentials

Two Stage, Series D-400 Switch Operating Specifications

When ordering, select operation desired, add suffix number to type number of 

control. Example: Type DA-431-4122.

Specification No. 4122.

 One circuit opens on increase of pressure; second circuit 

opens on further increase of pressure.

Specification No. 4129.

 One circuit closes on increase of pressure; second circuit 

closes on further increase of pressure.

Specification No. 4132. 

Both circuits open at intermediate pressure. One circuit 

closes on increase of pressure above neutral zone; second circuit closes on 

decrease in pressure below neutral zone.

Specification No. 4123. 

Both circuits close at intermediate pressure. One circuit 

opens on increase of pressure above neutral zone; second circuit opens on decrease 

in pressure below neutral zone.

Electrical Ratings D-400

See Code C on Page 5 in Electrical Rating Chart.

Range 

Number Adj. Working Range

Bourdon 

Tube Material

Minimum Pressure Spread 

Between Switch Operation

Fixed Differential Each 

Switch (Sensitivity)

For Steam and Other Applications: DA-431, -DAW-433, DAH-431
1

2

3

3A

4

5

6

7

8

9

27

1/8 to 15 psig

0 to 30 in Hg VAC

10 in VAC 12 psig

1/8 to 20 psig

1 to 35 psig

2 to 60 psig

5 to 100 psig

5 to 150 psig

5 to 200 psig

10 to 300 psig

25 in VAC 50 psig

Brass

Brass

Brass

Brass

Brass

Brass

Brass

Brass

Brass

Brass

Brass

2-1/2 psig

4 in Hg

2-1/2 psig

2-1/2 psig

3-1/2 psig

5 psig

7 psig

10-5/8 psig

15 psig

25 psig

7 psig

1/2 psig

1 in Hg VAC

1/2 psig

1/2 psig

3/4 psig

3/4 psig 

1 psig

1-1/8 psig

1-1/4 psig

2 psig

1 psig

For General Pressure Applications: DA-421, DAW-423, DAH-421
5S

6S

8S

9S

9AS

10S

11S

12S

13S

15S

25S

26S

2 to 60 psig

5 to 100 psig

10 to 200 psig

10 to 300 psig

40 to 350 psig

25 to 600 psig

50 to 1000 psig

100 to 1500 psig

300 to 2500 psig

500 to 5000 psig

30 in Hg VAC 60 psig

30 in Hg VAC 75 psig

Steel

Steel 

Steel

Steel

Steel

Steel

Steel

Steel

Steel

Steel

Steel

Steel

6 psig

8 psig

10 psig

20 psig

20 psig

40 psig

100 psig

150 psig

250 psig

600 psig

5 psig

10 psig

1-1/4 psig

2 psig

2 psig

4 psig

4 psig

7 psig

10 psig

12 psig

20 psig

150 psig

1 psig

2 psig

316 SS Bourdon Tubes: DA-441, DAW-443, DAH-441
26E

23E

6E

24E

9E

21E

22E

11E

13E

30 in Hg VAC 75

5 to 75 psig

10 to 100 psig

10 to 150 psig

10 to 300 psig

30 to 400 psig

75 to 800 psig

100 to 1000 psig

200 to 2500 psig

316 SS

316 SS

316 SS

316 SS

316 SS

316 SS

316 SS

316 SS

316 SS

12 psig

12 psig

12 psig

13 psig

35 psig

40 psig

85 psig

125 psig

275 psig

2 psig

2 psig

2 psig

3 psig

6 psig

8 psig

15 psig

22 psig

75 psig

Summary of Contents for D Series

Page 1: ...ght across the two cover screws or check the lower end of the glass opening in the cover to see that the control is lined up horizontal ly On general purpose controls provided with a flange mount by means of the three holes in the flange SPECIFICATIONS Wetted Materials Brass 403 SS or 316 SS Temperature Limit 180 F 82 C Pressure Limit Maximum pressure of the operating range Enclosure rating Genera...

Page 2: ...ing Again install firmly in a level position Do not mount the control by twisting the case use a wrench on the square part of the 1 4 bottom pipe connection Be sure pipe connection is in a vertical position After cover is properly attached with the name plate on bottom of the cover sight across the lower end of the glass opening in the cover to see that the control is lined up vertically Do not us...

Page 3: ...l full scale Minimum Differential listed below Fixed Differenital Single Adjustment Adjustable operating point Differential fixed NOT ADJUSTABLE APPLICATION Bourdon tube Material Adjustable Operating Range psig Range Number DA 31 DA 531 DS 231 Brass Bourdon Tubes 0 30 Hg VAC 10 in Hg VAC 12 1 8 to 15 psig 1 8 to 20 psig 1 to 35 psig 25 in Hg VAC 50 2 to 60 psig 5 to100 psig 5 to 150 psig 10 to 200...

Page 4: ...sitivity For Steam and Other Applications DA 431 DAW 433 DAH 431 1 2 3 3A 4 5 6 7 8 9 27 1 8 to 15 psig 0 to 30 in Hg VAC 10 in VAC 12 psig 1 8 to 20 psig 1 to 35 psig 2 to 60 psig 5 to 100 psig 5 to 150 psig 5 to 200 psig 10 to 300 psig 25 in VAC 50 psig Brass Brass Brass Brass Brass Brass Brass Brass Brass Brass Brass 2 1 2 psig 4 in Hg 2 1 2 psig 2 1 2 psig 3 1 2 psig 5 psig 7 psig 10 5 8 psig ...

Page 5: ...ose Opens 155 1 Circuit 2 Circuit B Closes Open 156 SP DT A One Closes as Other Opens 705 SP DT SP DT B A One Closes as Other Opens Opens 729 SP ST SP DT B A One Closes as Other Opens Opens 804 DP DT B Two Close Two Open 815 B 4P ST Close 2 9 67 816 B 4P ST Open 2 9 67 Consult factory ELECTRICAL RATING CHART Code Circuit Suffix AC Capacity DC Capacity Horsepower 120 V 240 V 440 V 120 V 240 V AC DC...

Page 6: ... HOLES 3 4 CONDUIT CONNECTION BREATHER OPTIONAL MOUNTING HOLES OPTIONAL 3 1 2 88 90 9 7 8 250 83 5 127 4 Ø7 16 11 23 MOUNTING HOLES 7 5 8 193 7 10 13 16 274 7 6 7 8 174 6 10 11 16 271 5 3 4 NPT CONNECTION TYP Explosion proof prefixed by DAH DAHF DRH DSH DSHF Watertight NEMA 2 3 4 Prefixed by DAW DRW DSW DLW Explosion proof prefixed by DAE DLE DRE DSE ...

Page 7: ...__________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ _______________________________________________________________________________________...

Page 8: ...______________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ ___________________________________________...