background image

Free Standing

 

Bulb Warmer Service Manual 

 

  5

B1-2 – SPAER PARTS LIST, 120V & 240V 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ITEM 

PART # 

DESCRIPTION 

000179 

BUSHING, HEYCO, SR-6N-3-4, BLACK 

060334 

PLUG, 1”, SQ, PLASTIC, BLK, DRILLED 

000671 

SOCKET, B-2, PORC KEYLESS LH, 14” 

000638 

SHADE, ALUM, #500, SATIN-CLEAR 

000371 

LAMP, 120V, 250W, CLR, HEAT, 250R40 

 

000372 

LAMP, 120V, 250W, RED, 250R40 

 

000373 

LAMP, 120V, 250W, CLR, HEAT COAT, 250R40 

 

000379 

LAMP, 240V, 250W, RED HEAT, 250R40 

000580 

SCREW 6-32 x ¼ TRH, PHH, NIK 

060304 

ARM, B1-2, ALUM, POLISH AND TAP 

 

060305 

ARM, B1-2, ALUM, POLISH AND TAP 

000619 

KNOB, ¼-28 X ¼, MALE, BLACK 

11 

000311 

CORDSET, 120V, W/INLINE SWITCH 

 

060260 

CORDSET, 240V, W/SWITCH, B-2 

12 

060314 

BASE WELD, B1-2 (NEW-STYLE) 

 
 

Summary of Contents for B1

Page 1: ...tion found in this manual will prove very helpful Although the instructions are easy to follow all repair procedures should be carried out be a qualified Merco Savory Service Representative Merco Free Standing Bulb Warmers are manufactures from specially selected alloys for long life and easy cleaning Models are available in 1 2 and 3 bulb configurations as well as a special 3 bulb unit for most c...

Page 2: ...ESS LH 14 4 000638 SHADE ALUM 500 SATIN CLEAR 5 000371 LAMP 120V 250W CLR HEAT 250R40 000372 LAMP 120V 250W RED 250R40 000373 LAMP 120V 250W CLR HEAT COAT 250R40 000379 LAMP 240V 250W RED HEAT 250R40 6 000580 SCREW 6 32 x TRH PHH NIK 8 060301 ARM B1 ALUM POLISH AND TAP 9 000619 KNOB 28 X MALE BLACK 11 000311 CORDSET 120V W INLINE SWITCH 060260 CORDSET 240V W SWITCH B 2 12 060331 BASE WELD B1 NEW S...

Page 3: ...ESS LH 14 4 000638 SHADE ALUM 500 SATIN CLEAR 5 000371 LAMP 120V 250W CLR HEAT 250R40 000372 LAMP 120V 250W RED 250R40 000373 LAMP 120V 250W CLR HEAT COAT 250R40 000379 LAMP 240V 250W RED HEAT 250R40 6 000580 SCREW 6 32 x TRH PHH NIK 8 060302 ARM B2 ALUM POLISH AND TAP 9 000619 KNOB 28 X MALE BLACK 12 000311 CORDSET 120V W INLINE SWITCH 060260 CORDSET 240V W SWITCH B 2 13 060332 BASE WELD B2 NEW S...

Page 4: ...ESS LH 14 4 000638 SHADE ALUM 500 SATIN CLEAR 5 000371 LAMP 120V 250W CLR HEAT 250R40 000372 LAMP 120V 250W RED 250R40 000373 LAMP 120V 250W CLR HEAT COAT 250R40 000379 LAMP 240V 250W RED HEAT 250R40 6 000580 SCREW 6 32 x TRH PHH NIK 8 060303 ARM B3 ALUM POLISH AND TAP 9 000619 KNOB 28 X MALE BLACK 12 000311 CORDSET 120V W INLINE SWITCH 060260 CORDSET 240V W SWITCH B 2 13 060333 BASE WELD B3 NEW S...

Page 5: ...SHADE ALUM 500 SATIN CLEAR 5 000371 LAMP 120V 250W CLR HEAT 250R40 000372 LAMP 120V 250W RED 250R40 000373 LAMP 120V 250W CLR HEAT COAT 250R40 000379 LAMP 240V 250W RED HEAT 250R40 6 000580 SCREW 6 32 x TRH PHH NIK 8 060304 ARM B1 2 ALUM POLISH AND TAP 060305 ARM B1 2 ALUM POLISH AND TAP 9 000619 KNOB 28 X MALE BLACK 11 000311 CORDSET 120V W INLINE SWITCH 060260 CORDSET 240V W SWITCH B 2 12 060314...

Page 6: ...socket and shade from the arm 6 Locate wires for the socket you are replacing and attach an old piece of wire or string before pulling socket wires through the arm 7 Remove socket and shade by pulling on socket until wire ends are exposed 8 Attach pullwire to wire leads on new socket see 6 9 Pull pullwire through arm until socket and shade are touching arm 10 Reattach shade and socket with screws ...

Page 7: ...sed to supply electricity to the unit has a sufficient amerage rating 3 Use the correct NEMA receptacle that corresponds to the plug provided on the unit 4 Place unit on a flat and level surface 5 Insert the NEMA plug into the proper NEMA receptacle WIRING DIAGRAMS B 1 B 2 B 3 250 W INFRARED HEAT LAMP 250 W INFRARED HEAT LAMP WIRING DIAGRAM 120V 208 240V 250 WATT LAMPS CAUTION DISCONNECT POWER WHE...

Page 8: ...der this Limited Warranty and any responsibility or obligations associated therein null and void This includes any damage costs or legal actions resulting from the installation of any Merco commercial cooking equipment in a non commercial application or installation where the equipment is being used for applications other than those approved for by Merco LIMITATIONS OF LIABILITY The preceding para...