background image

50mm Screw x 20 

40mm Screw x 38 

20mm Screw x16

30mm Screw x65

60mm Screw x 24

30mm Black Screw x3

P 2

04VCGRO-V2

Overall Dimensions:

Width =1778mm 

Depth = 861mm 

Height = 1944mm

Base Dimensions: 

Width = 1730mm 

Depth = 821mm 

Please retain product label and instructions for future reference

             

Before assembly  

please make sure you have a 

suitable base ready to erect your 

building 

 

MADE IN GREAT BRITAIN

Left Side Panel

AI-04VCGROSPL821X1840-V2

Right Side Panel

AI-04VCGROSPR821X1840-V2

Back Panel

AI-04VCGROBP821X1840-V2

QTY 2

Door

AI-04VCGROD410X1640-V2

QTY 4

Roof

AI-04VCGROR876X860-V2

QTY 2

Shelf A

AI-04VCGROSHA440X715-V2 

QTY 2

Shelf B

AI-04VCGROSHB275X821-V2

Framing  - 27x44x1642mm QTY 3 

F2744-1642mm

Strip  - 7x27x410mm QTY 2 

S727-410mm

Cover trim - 12x56x1840mm QTY 2  

S1256-1840mm

Cover trim - 12x56x1713mm QTY 2  

S1256-1713mm

Door trim - 12x56x1595mm QTY 1  

S1256-1595mm 

2

1

3

4

5

6

7

21

8

9

11

12

13

14

15

17

18

19

20

10

Roof trim - 12x56x860mm QTY 3 

S1256-860mm

Base framing - 44x44x733mm QTY 2 

F4444-733mm

Base framing - 44x44x1730mm QTY 2 

F4444-1730mm

‘L’ Bracket

PI-07-0012

QTY 4

Butt hinge

PI-07-0066

QTY 2

Tower bolt

PI-07-0114

QTY 2

Butterfly hinge

PI-07-0004

QTY 6

Turn button

PI-07-0182

QTY3

16

Roof support block - 27x44x140mm QTY 1

F2744-140mm

Summary of Contents for 04VCGRO-V2

Page 1: ...d periods of rain swelling of the wood panels may occur Warping of the wood may also occur during excessive dry spells due to an interior moisture loss Unfortunately these processes cannot be avoided but can be helped It is suggested that the outdoor building is sprayed with water during extended periods of warm sunshine and sheltered as much as possible during rain or snow Once your garden buildi...

Page 2: ...Door AI 04VCGROD410X1640 V2 QTY 4 Roof AI 04VCGROR876X860 V2 QTY 2 Shelf A AI 04VCGROSHA440X715 V2 QTY 2 Shelf B AI 04VCGROSHB275X821 V2 Framing 27x44x1642mm QTY 3 F2744 1642mm Strip 7x27x410mm QTY 2 S727 410mm Cover trim 12x56x1840mm QTY 2 S1256 1840mm Cover trim 12x56x1713mm QTY 2 S1256 1713mm Door trim 12x56x1595mm QTY 1 S1256 1595mm 2 1 3 4 5 6 7 21 8 9 11 12 13 14 15 17 18 19 20 10 Roof trim ...

Page 3: ... 60mm screw Step 2 Position the Left Side Panel No 1 next to the Back panel No 2 as shown and secure with 3x40mm screws Do NOT secure to the base framing until the Roof is fitted 3x40mm screws Pre drill hole 40mm screw Step 3 Fix the second Back panel No 2 side by side to the existing Back panel as shown with 3x40mm screws Position the Right Side Panel No 3 to next to the Back panel No 2 as previo...

Page 4: ... of the framing 8x40mm screws 8x60mm screws Step 4 In order for the static doors to be fixed in position Fix the Strips No 9 to two of the doors as shown with 2x30mm screws per door 4x30mm screws Pre drill hole 60mm screw Pre drill hole 30mm screw Step 6 Place the Static Door frame in postion and fix with 60mm screws securing from the outside as shown Do NOT secure to the base framing until the Ro...

Page 5: ...or second shelf 8x20mm screws Step 10 Attach the Butterfly hinges No 21 to the Doors No 4 using 4x30mm screws per hinge as shown Fix the Doors to the building as shown using 4x30mm screws 16x30mm screws Pre drill hole 20mm screw Step 11 Once the Doors are fitted Determine which door is to be the Master door and attach 2xTurn buttons No 18 to the outside of the door with 2x30mm black screws so that...

Page 6: ...le into Shelf A 14x30mm screws Lower view Upper view Step 13 Fix the Static Roof No 5 into postion with 4x60mm screws at the rear and 4x40mm at the front Make sure the side of the Roof panel is flush with the side of the building 4x40mm screws 4x60mm screws Step 14 To fix the opening Roof No 5 place in postion so it aligns with the fixed Roof Make sure the side of the Roof panel is flush with the ...

Page 7: ...ws 6x30mm screws 3x40mm screws Step 16 Fix the Cover trims No 10 No 11 as shown with 3x30mm screws per trim 12x30mm screws Step 17 Fix the Roof support block No 16 to the inside of the side panel with 1x50mm screw This block allows for the Opening Roof to be kept open as shown 1x50mm screws Step 18 Fix the building to the base with 50mm screws evenly spaced as shown 18x50mm screws Pre drill hole 4...

Page 8: ...pply wood treatment immediately after the building has been assembled AFTER TREATMENT score around protective cover on glazing and carefuly peel covering back Please retain product label and instructions for future reference P8 ...

Reviews: