Mercia Garden Products 01OVLPRA0604SDFW-V1 General Instructions Manual Download Page 1

N/A

Overlap

Cladding

Shiplap

Cladding

Solid Sheet

Roof

T&G Roof

Solid Sheet

Floor

T&G Floor

Fixed

Windows

Opening

Windows

No

Windows

For Assistance Please 

Contact Customer Care on 

01636 880514

2mm Drill bit

x2

Winter = High Moisture = Expansion

Summer = Low Moisture = Contraction

All building’s should be erected by two 

adults

For ease of assembly, it is advisable to 

pilot drill all screw holes and ensure 

all screw heads are countersunk.

BEFORE YOU START PLEASE READ INSTRUCTIONS CAREFULLY 

- Check the pack and make sure you have all the parts listed. 

- When you are ready to start, make sure you have the right tools at hand 

(

not supplied) 

including

 

 a Phillips screwdriver, Stanley knife, wood saw, 

step ladder and drill with 2mm bit.

- Ensure there is plenty of space and a clean dry area for assembly. 

TIMBER

As with all natural materials, timber can be affected during various weather 

conditions. For the duration of heavy or extended periods of rain, swelling of the 

wood panels may occur. Warping of the wood may also occur during excessive 

dry spells due to an interior moisture loss. Unfortunately, these processes cannot 

be avoided but can be helped. It is suggested that the outdoor building is 

sprayed with water during extended periods of warm sunshine and sheltered as 

much as possible during rain or snow. 

Our buildings are pre treated with a water based treatment**; this only helps to 

protect the product during transit and for upto 3 months against mould.  To 

validate your guarantee and ensure longevity of the product, it is ESSENTIAL the 

building is treated with a wood preserver within the first three months of 

assembly and thereafter in accordance with the manufactures recommenda-

tions.  Care must be taken to ensure the product is placed on a suitable base.

BUILDING A BASE

When thinking about where the building and base is going to be constructed: 

Ensure that there will be access to all sides for maintenance work and annual 

treatment.

Whilst all products manufactured  are made to the 
highest standards of Safety and in the case of childrens 
products independently tested to EN71 level, we cannot 
accept responsibility for your safety whilst erecting or 
using this product.

Mercia Garden Products Limited, Sutton On Trent, Newark, Nottinghamshire, NG23 6QN

www.merciagardenproducts.co.uk

CAUTION

Every effort has been made during the 

manufacturing process to eliminate the 

prospect of splinters on rough surfaces 

of the timber.  You are strongly advised 

to wear gloves when working with or 

handling rough sawn timer.

**Protim Fentex E5**

Biocidal Product Regulation (EU 528/2012) 

Article 58 Information

Protim Fentex E2 preserved wood is a “treated article” which incorporates biocidal products. 

Wood correctly preserved with Protim Fentex E2 is protected against mould in storage. 

Contains: IPBC (3-iodo-2-propynyl-N-butyl carbamate) and propiconazole.

Wear gloves when handling freshly treated wood. 

Avoid breathing dust when cutting treated or untreated wood. 

Dispose of off-cuts responsibly – do not burn.

Ensure the base is level and is built on firm ground, to prevent distortion.  Refer 

to diagrams for the base dimensions,  The base should be slightly smaller than 

the external measurement of the building, i.e. The cladding should overlap the 

base, creating a run off for water. It is also recommended that the floor be at 

least 25mm above the surrounding ground level to avoid flooding.

TYPES OF BASE

- Concrete 75mm laid on top of 75mm hard-core.

- Slabs laid on 50mm of sharp sand.

Please retain product label and instructions for future reference

             

P 1

General Instructions

Refer to the instructions pages for you spoecific product code

01OVLPRA0604SDFW-V1

6x4 Overlap Reverse Apex Single Door Fixed Window

01OVLPRA0606SDFW-V1

6x6 Overlap Reverse Apex Single Door Fixed Window

01OVLPRA0806SDFW-V1

8x6 Overlap Reverse Apex Single Door Fixed Window

01OSBRA0806SDFW-V1

8x6 Shiplap Reverse Apex Single Door Fixed Window

01OVLPRA1006SDFW-V1

10x6 Overlap Reverse Apex Single Door Fixed Window

Summary of Contents for 01OVLPRA0604SDFW-V1

Page 1: ...all sides for maintenance work and annual treatment Whilst all products manufactured are made to the highest standards of Safety and in the case of childrens products independently tested to EN71 lev...

Page 2: ...Eaves Frame 1502mm Qty 4 Fascia 1016mm Qty 4 Finial x2 Truss Frame 932mm Qty 2 Truss Support Bar 450mm Qty 1 Truss Block 140mm Qty 2 Door Block 140mm Qty 1 Panel Block 120mm Qty 2 14 15 16 17 18 23 Wi...

Page 3: ...ladding on all 4 sides Step 2 2 3 7x50mm Screws Pre drill hole 50mm screw 6 Step 3 13x50mm Screws Fix the corners with 50mm screws as shown in diagram Pre drill hole 50mm screw 1 3 6 Step 4 24 8 8 22...

Page 4: ...to the truss frame and flush with the underneath of the panels fram ing Screw through the ouside of the building through the clad ding into the panel block using 2x 30mm screw per block 4x30mm Screws...

Page 5: ...the remaining two roof sheets in the same way 60x40mm Screws 12x30mm Screws Fix the eaves frame to the roof sheet using 3x30mm screws for each sheet b b 40mm screw Pre drill hole 7 12 Step 10 b Once t...

Page 6: ...Pre drill hole 15 40mm screw 15 18 18 15 15 Please retain product label and instructions for future reference Step 14 Fit the window into the opening on the door panel and fix in place with 6x 20mm sc...

Page 7: ...olt retainer to the door panel framing using 4x30mm screws Fix the turn buttons using 1x30mm black screw per turn button 23 30mm screw 21 30mm screw 2x 30mm Black Screw 10x 30mm Screw It is ESSENTIAL...

Reviews: