10
•
Depending on the desired rated power, the installation of the Wallbox may need to be registered with and/or approved by
the local electricity grid operator before the device is taken into operation. Please consult the regulations of your local
electricity grid operator.
•
Cable dimensions must be adjusted according to the desired rated power and other
aspects (such as cable length, material, cabling method etc.). The terminal blocks in the
Wallbox are designed for cable dimensions from 1.5 mm
2
to 16 mm
2
.
•
The power supply cable may be installed above or below the wall surface. If the power
supply cable is installed above-surface, a cable guide is provided at the back of the hous-
ing to guide the cable to the terminals area of the housing base.
•
The power supply for the Wallbox must always be protected by its own MCB (rated cur-
rent depending on the power supply and Wallbox settings, but no more than 32 A). Please
always observe the applicable national requirements regarding the selection of the MCB.
•
If you want to take the Wallbox out of operation, switch the upstream domestic MCB and
the internal RCCB to the
0
(OFF) position.
•
Please always ensure that the installation requirements listed in this manual are complied with. Disregard or actions to the
contrary may lead to severe, even fatal injury by electric shock. In addition, in case of contravention of the notices given,
the proper operation of the Wallbox cannot be guaranteed.
PLEASE NOTE!
In order to achieve the maximum charging output of the Wallbox, the power supply cable must be dimensioned and
installed for 32 A. The maximum charge current (see “Setup and test modes” on page 15) must also be set to 32 A.
Factory settings are 16 A for the A0009067408 and 32 A for the A0009067508 model variant.
PLEASE NOTE!
In some countries, the above-mentioned requirements are different from the prerequisites for connecting to the local
power grid. In this case, the Wallbox must be connected in accordance with the respective type of mains power connec-
tion for the country of installation. You can find an overview of country-specific mains connection schemes on page 28
in this manual or on the
www.yourwallbox.de
website via the following link:
www.yourwallbox.de/downloads/documents/Mains_Connection_Schemes_Home_Advanced.pdf
Mechanical and electrical installation
After determining the mounting site for the Wallbox, you can begin with mechanical installation. For mechanical installation,
you will need the following components:
•
Power drill or cordless drill (not included)
•
Drill bit Ø 8 mm, appropriate for the wall material (not included)
•
Drilling template for the Wallbox model variants described in this manual (included)
•
Torx bit screwdrivers (TX20, TX30) (not included)
•
VDE blade screwdrivers (blade thickness and length: 0.5 x 2.5 mm, 80 mm recommended) (not included)
•
Cutter for cutting the rubber grommet to insert the supply cable (not included)
•
Four 6 x 60 chipboard screws for fixing the housing base (included)
•
If required: Wall plugs suitable for the mounting substrate (included: 8 x 40 nylon wall plugs)
•
Spirit level if required (not included)