18
6
LOCATION OF THE COOKER
•
SiThe cooker is mainly for indoor use over 20 m².
•
Always ensure that adequate ventilation is provided.
•
Always maintain an adequate distance to combustible materials, i.e. 100 cm above and 100 cm to the
sides as a minimum.
•
The cooker must be placed on a firm and level floor.
•
Never place the cooker in an explosive atmosphere such as in areas where gasoline or other flammable
liquids or gases are stored.
GAS REQUIREMENTS
•
Use propane or butane gas only.
•
The pressure regulator and hose assembly to be used must meet local code standards.
•
The installation must comply with local codes or, in the absence of local codes, with the standard for the
storage and handling of liquefied petroleum gases.
•
A dented, rusted or damaged cylinder can be dangerous and should be checked by your cylinder supplier.
Never use a cylinder with a damaged valve connection.
LEAK TEST
•
The gas connections of the cooker are leak tested at the factory prior to shipment. A complete gas
tightness check must be performed at the installation site due to possible mishandling during shipment or
application of excessive pressure to the cooker.
•
Make a soap solution of one part liquid detergent and one part water. The soap solution can be applied
with a spray bottle, brush or rag. Soap bubbles will appear in case of a leak.
•
Make sure the safety control valve is in the OFF position. Turn on the gas supply.
•
In the event of a leak, turn off the gas supply. Tighten leaking fittings, then turn on the gas supply and
recheck.
•
Never leak test while smoking.