![Menvier Security DC58M+ Installation & Programming Instructions Download Page 9](http://html1.mh-extra.com/html/menvier-security/dc58m/dc58m_installation-and-programming-instructions_1771178009.webp)
Programming
Programming Menu
9
DC58M+ Installation Instructions
Programming
TELEPHONE NO.1
018112345678
TELEPHONE NO.2
018112345687
REPORTS TO NO.1
* * 3 4 * * * 8
Enter Telephone No. 1
Press any key
= Clear number
= Pulse Dial (P) or Pause (-)
= Tone Dial (T)
DC58M+ Vers 1.0
Press Any Key
Enter Telephone No. 2
TELEPHONE NO.3
018112345679
ACCOUNT NO.1
0001
Enter Telephone No.3
Enter account No.1
ACCOUNT NO.2
0001
ACCOUNT NO.3
0001
Enter account No. 2
Enter account No. 3
Select channels that report
to tel No.1 by pressing [1] - [8]
REPORTS TO NO.2
* 2 3 4 * * * 8
REPORTS TO NO.3
* 2 3 4 * * * 8
Select channels that report
to tel No.2 by pressing [1] - [8]
Select channels that report
to tel No.3 by pressing [1] - [8]
SET/DAY CHANNELS
* * * 4 * * * *
Select Set/Day (Open/Close)
channels by pressing [1] - [8]
RESTORE CHANNELS
* * 3 4 * * * *
Select Restore channels
by pressing [1] - [8]
= Consecutive
= Alternative
= All
Dialling Mode
is Consecutive
Select dialling mode:
= Disabled
= Daily
= Weekly
TEST CALL PERIOD
Disabled
Select test call period:
= Fortnightly
Digi Format
Standard
Select output type:
= Standard
= Extended Limited
= Extended Full
= Disabled
= Daily
= Weekly
T.O.S Calls are
Disabled
Select Temporary Out of
Service monitoring period:
= Fortnightly
3-WAY CALLING
Enabled
Enable/Disable 3-way calling:
= Disable
= Enabled
Finish