Regulatory Requirements
General
The DC58M+ digital communicator/modem
must be installed by an electrically competent
person. Before attempting to install the DC58M+,
the installer must be aware of the following:
Application
The DC58M+ digital communicator/modem is
suitable for connection to the following types of
telephone line:
l
Direct exchange lines (PSTN) supporting DTMF
(Tone dialling).
l
PABX exchanges (with or without secondary
proceed indication).
Approval
The DC58M+ digital communicator/modem is
not suitable for connection as an extension to a
pay phone or 1+1 carrier systems. The DC58M+
digital communicator/modem is approved for the
following usage:
l
Automatic call initialisation
l
Operation in absence of proceed indication
l
Automatic dialling
l
Multiple repeat attempts
l
Serial connection
l
Three-way calling using BT Network Services
l
Modem
Usage other than the approved usage or failure to
comply with the installation and programming
instructions may invalidate any approval given to
the apparatus. The approval Label for the
DC58M:
This product is manufactured to meet all
European Economic Area Telecommunication
networks requirements.
Connections
Connection terminals on the DC58M+ are
described as either
"Safety Extra-Low Voltage"
circuits (SELV) or
"Telecommunications Network
Voltage"
circuits (TNV).
The PCB layouts on page 7 shows the two types of
circuits.
+
It is important that the installer ensures that
TNV connections are only connected to
the PSTN and SELV circuits are only
connected to other circuits designated as
SELV circuits.
+
Interconnection circuits should be such
that the equipment continues to comply
with the requirements of 4.2 of EN 41003
for TNV circuits and 2.3 of EN 60950 for
SELV circuits, after making connections
between circuits.
Mounting The DC58M+
The DC58M+ is supplied inside a polycarbonate
enclosure and is small enough to be mounted
inside most control panels.
+
Once the unit is installed the cover must be
secured using the screws supplied.
Compatibility with PABXs
The DC58M+ is only approved for use with
compatible PABX systems. Correct operation in all
circumstances is not guaranteed. If you
experience any difficulties contact Menvier
Technical Support.
3
DC58M+ Installation Instructions
Regulatory Requirements
0186