Menvier Security DC58M+ Installation & Programming Instructions Download Page 3

Regulatory Requirements

General

The DC58M+ digital communicator/modem
must be installed by an electrically competent
person. Before attempting to install the DC58M+,
the installer must be aware of the following:

Application

The DC58M+ digital communicator/modem is
suitable for connection to the following types of
telephone line:

l

Direct exchange lines (PSTN) supporting DTMF

(Tone dialling).

l

PABX exchanges (with or without secondary

proceed indication).

Approval

The DC58M+ digital communicator/modem is
not suitable for connection as an extension to a
pay phone or 1+1 carrier systems. The DC58M+
digital communicator/modem is approved for the
following usage:

l

Automatic call initialisation

l

Operation in absence of proceed indication

l

Automatic dialling

l

Multiple repeat attempts

l

Serial connection

l

Three-way calling using BT Network Services

l

Modem

Usage other than the approved usage or failure to
comply with the installation and programming
instructions may invalidate any approval given to
the apparatus. The approval Label for the
DC58M:

This product is manufactured to meet all
European Economic Area Telecommunication
networks requirements.

Connections

Connection terminals on the DC58M+ are
described as either

"Safety Extra-Low Voltage"

circuits (SELV) or

"Telecommunications Network

Voltage"

circuits (TNV).

The PCB layouts on page 7 shows the two types of
circuits.

+

It is important that the installer ensures that

TNV connections are only connected to

the PSTN and SELV circuits are only

connected to other circuits designated as

SELV circuits.

+

Interconnection circuits should be such

that the equipment continues to comply

with the requirements of 4.2 of EN 41003

for TNV circuits and 2.3 of EN 60950 for

SELV circuits, after making connections

between circuits.

Mounting The DC58M+

The DC58M+ is supplied inside a polycarbonate
enclosure and is small enough to be mounted
inside most control panels.

+

Once the unit is installed the cover must be

secured using the screws supplied.

Compatibility with PABXs

The DC58M+ is only approved for use with
compatible PABX systems. Correct operation in all
circumstances is not guaranteed. If you
experience any difficulties contact Menvier
Technical Support.

3

DC58M+ Installation Instructions

Regulatory Requirements

0186

Summary of Contents for DC58M+

Page 1: ...DC58M 8 Channel Digital Communicator Digi Modem Installation Programming Instructions...

Page 2: ...int ID Extended Format 6 Modem 6 Installation Plug on Installation 6 Telephone Line Connections 7 NETLCD TS900 Keypad Connections 7 Testing 8 Programming Programming Menu 9 Telephone Numbers 10 Accoun...

Page 3: ...l for the DC58M This product is manufactured to meet all European Economic Area Telecommunication networks requirements Connections Connection terminals on the DC58M are described as either Safety Ext...

Page 4: ...present The NVM can be programmed by using a Menvier LCD Remote Keypad P No NETLCD TS900 REM and an engineer s interface lead P No NETEKI which will plug directly on to the DC58M Alternatively the NV...

Page 5: ...call The unit then sends a Recall signal which is detected by the exchange as a request for a new line With a new line available the DC58M then attempts to connect with the ARC If the DC58M is connec...

Page 6: ...ation A LED 1 Activity LED On whilst communicator is active Flashes on and off 4 times when successfully communicated with the ARC Flashes continuously when modem is in operation B Test Call Short the...

Page 7: ...t and remove the bottom section from the master jack 6 Connect the cable from A and B terminals on the DC58M to the BT master jack terminals see Figure 4 7 A special insertion tool will be required to...

Page 8: ...rily shorting the TEST CALL pins together see Figures 3 This will initiate a test transmission to the ARC The DC58M will not send a test call if there is a parallel hand set off hook 4 Trigger all the...

Page 9: ...TO NO 2 2 3 4 8 REPORTS TO NO 3 2 3 4 8 Select channels that report to tel No 2 by pressing 1 8 Select channels that report to tel No 3 by pressing 1 8 SET DAY CHANNELS 4 Select Set Day Open Close ch...

Page 10: ...ently Account Numbers This is a 4 digit number that the alarm receiving centre uses to identify the alarm site Up to three account numbers can be programmed Account numbers can only be programmed if t...

Page 11: ...l details on the extended information refer to the relevant control panel Installation Manual This feature is only supported by relevant Menvier control panels for details on which control panels supp...

Page 12: ...ld show Other Monitor Messages The following monitor messages may also be displayed 12 Monitor Mode DC58M Installation Instructions DC58M MONITOR Waiting for I D DC58M MONITOR Sending Data Dialling th...

Page 13: ...Reports to No 1 Reports to No 2 Report to No 3 Set Day Channels Restore Channels Three way Calling Disabled o Enabled o Dialling Mode Consecutive o Alternative o All o Test Call Period Disabled o Dail...

Page 14: ...14 Monitor Mode DC58 58M Installation Instructions This page is intentionally blank...

Page 15: ...15 DC58 58M Installation Instructions Monitor Mode This page is intentionally blank...

Page 16: ...per Security Ltd Security House Xerox Business Park Mitcheldean Gloucestershire GL17 0SZ England Product Support Tel 01594 545556 Between 09 00 and 17 00 Monday to Friday Product Support Fax 01594 545...

Reviews: