![Menumaster DECS11MA Service Manual Download Page 26](http://html1.mh-extra.com/html/menumaster/decs11ma/decs11ma_service-manual_1771166026.webp)
COMPONENTS
TEST PROCEDURE
RESULTS
5-10
RELAY 2
Check for continuity of relay 2 with an
ohm-meter.
(Remove wire leads from relay 2 and
operate the unit.)
Measure the resistance.
(Ohm-meter scale: R x 1000)
Measure the resistance.
(Ohm-meter scale: R x 1000)
POWER
LEVEL
NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
• MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
Relay 2
FAN MOTOR
(Wire leads removed)
STIRRERFAN
MOTOR
(Wire leads removed)
1
2
3
4
5
6
7
8
9
10
3 sec
4 sec
5 sec
6 sec
7 sec
8 sec
9 sec
10 sec
11 sec
12 sec
9 sec
8 sec
7 sec
6 sec
7 sec
4 sec
3 sec
2 sec
1 sec
0 sec
Normal: Approx. 72 ~ 82 ohm
Abnormal: Infinite or several
K-ohm.
Normal: Approx. 12.8~13.5 kohm
Abnormal: Infinite or several
ohm.
Summary of Contents for DECS11MA
Page 15: ...SCHEMATIC DIAGRAM 4 9...
Page 35: ...6 4 2012 2400 2005 2006 2381 2000 W130 W102 CONTROL PANEL PARTS MODEL DFS11G EV...
Page 36: ...6 5 2012 2400 2005 2006 2381 W130 2000 2002 W102 CONTROL PANEL PARTS MODEL DECS11MA UCS11MA EV...
Page 37: ...2004 2381 2000 2002 2006 W130 W102 CONTROL PANEL PARTS MODEL DES11EA US11EA 6 6 EV...
Page 38: ...6 7 2004 2006 2381 W130 W102 2000 CONTROL PANEL PARTS MODEL DFS11EA UFS11EA EV...
Page 43: ...7 1 SCHEMATIC DIAGRAM OF P C B...
Page 44: ...7 2 PRINTED CIRCUIT BOARD...