![Menumaster DECS11MA Service Manual Download Page 18](http://html1.mh-extra.com/html/menumaster/decs11ma/decs11ma_service-manual_1771166018.webp)
MEASUREMENT WITH OUTER CASE
REMOVED
• When you replace the magnetron, measure for
microwave energy leakage before the outer case is
installed and after all necessary components are
replaced or adjusted.
Special care should be taken in measuring the
following parts. (Circled area of below Fig.)
- Around the magnetron
- The waveguide
MEASUREMENT WITH A FULLY
ASSEMBLED OVEN
• After all components, including the outer case, are fully
assembled, measure for microwave energy leakage
around the door viewing window, the exhaust opening,
and air inlet openings.
• Microwave energy leakage must not exceed the values
prescribed below.
NOTE: Leakage with the outer case removedless than
5 mW/cm
2
.sq. Leakage for a fully assembled
oven (Before the latch switch (primary) is
interrupted) with the door in a slightly opened
position-less than 2 mW/cm
2
.sq.
NOTES WHEN MEASURING
• Do not exceed meter full scale deflection.
• The test probe must be removed no faster than
1 inch/sec (2.5 cm/sec) along the shaded area,
otherwise a false reading may result.
• The test probe must be held with the grip portion of the
handle.
A false reading may result if the operator's hand is
between the handle and the probe.
• When testing near a corner of the door, keep the probe
perpendicular to the surface making sure the probe
horizontally along the oven surface, this may possibly
cause probe damage.
RECORD KEEPING AND NOTIFICATION
AFTER MEASUREMENT
• After adjustment and repair of any microwave energy
interruption or microwave energy blocking device,
record the measured values for future reference. Also
enter the information on the service invoice.
• The microwave energy leakage should not be more
than 4 mW/cm
2
.sq. after determining that all parts are
in good condition, functioning properly and genuine
replacement parts which are listed in this manual have
been used.
• At least once a year, have the electromagnetic energy
leakage monitor checked for calibration by its
manufacturer.
5-2
WARNING : AVOID CONTACTING ANY
HIGH VOLTAGE PARTS
Summary of Contents for DECS11MA
Page 15: ...SCHEMATIC DIAGRAM 4 9...
Page 35: ...6 4 2012 2400 2005 2006 2381 2000 W130 W102 CONTROL PANEL PARTS MODEL DFS11G EV...
Page 36: ...6 5 2012 2400 2005 2006 2381 W130 2000 2002 W102 CONTROL PANEL PARTS MODEL DECS11MA UCS11MA EV...
Page 37: ...2004 2381 2000 2002 2006 W130 W102 CONTROL PANEL PARTS MODEL DES11EA US11EA 6 6 EV...
Page 38: ...6 7 2004 2006 2381 W130 W102 2000 CONTROL PANEL PARTS MODEL DFS11EA UFS11EA EV...
Page 43: ...7 1 SCHEMATIC DIAGRAM OF P C B...
Page 44: ...7 2 PRINTED CIRCUIT BOARD...