32
FV36
85-03-01014
CONVERTING FIREPLACE FOR LP GAS
Caution
: The electrical supply to the fireplace must be turned off prior to performing the conversion. The gas
supply must be shut off prior to disconnecting the electrical power.
Orifice Sizes Requirement
A natural gas to LP gas conversion kit #HA-110-00084 must be ordered and installed in this fireplace to burn
LP gas.
LP conversion kit #HA-110-00084 contains the following parts: one motorized LP pressure regulator
#907.012, two cap orifices #65-14-00054 (
drill #54),
an L-shaped Torx wrench and an LP conversion label.
Procedure to Convert Fireplace for LP Gas
This fireplace arrives from the factory ready to burn natural gas. If you intend to burn LP gas, it is highly
recommended that you convert this fireplace and its pressure regulator, pilot natural gas/LP clip position and
burner orifices prior to placing this fireplace in its fireplace cavity.
Follow the step below to prepare this fireplace for conversion to LP gas:
1.
Using a ¼”
hex driver, remove the 3 screws that secure the rear and front burners to the burner airbox.
2.
Lift up and remove the burners.
3.
Using a ¼”
hex driver, remove the two screws that secure the airbox to the fireplace floor.
4.
Lift up and remove the airbox.
LP CONVERSION LABEL
(MUST BE FILLED OUT AND
ATTACHED TO FIREPLACE)
MOTORIZED LP REGULATOR
[10.0"-5.5" WC] #907.012
TORX WRENCH
BURNER ORIFICE
#54
WARNING:
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically
approved with this appliance may result in property damage or personal injury.
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions
and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions
is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage,
personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation of the converted appliance is checked as specified in the
owner instructions supplied with the kit.