3.4
PLUMBING TECHNICAL REFERENCES
Gas Supply Requirements
NOTE: if Fireplace is to be operated with LP gas, see Chapter
3.10 Natural Gas to LPG Conversion
in this
manual before proceeding.
CORRECT GAS PRESSURE AND PROPER GAS SUPPLY LINE SIZING IS IMPERATIVE TO THE SUCCESSFUL PERFORMANCE OF YOUR
MENDOTA GAS FIREPLACE. BE SURE THE GAS SUPPLIER OR PLUMBER CAREFULLY CHECKS FOR CORRECT GAS PRESSURE AND
GAS LINE SIZING WHEN INSTALLING THE FIREPLACE.
IT IS CRITICAL TO CAREFULLY CHECK FOR GAS LEAKS WHEN HOOKING UP THE FIREPLACE. CHECK WITH SOAP AND WATER
SOLUTION OR COMBUSTIBLE GAS SNIFFER.
BE SURE TO INSTALL CSST FLEX GAS LINE WITH BRASS-TO-BRASS FITTINGS TO PREVENT GAS LEAKS AT CONNECTIONS.
GAS SUPPLY PIPING MUST INCLUDE A DRIP LEG TO ELIMINATE THE POSSIBILITY OF CONTAMINANTS ENTERING THE GAS
TRAIN. ADHERE STRICTLY TO LOCAL AND NATIONAL CODES.
Gas Supply Line Sizing
This Mendota Gas Fireplace comes equipped with a 1/2" N.P.T. Female inlet. Gas supply piping must enter the Fireplace cabinet
on the left side.
Use the table, below, to determine the proper gas line diameter that must be installed to run from the supply regulator to the
factory installed manual shutoff valve. Refer to the following table for proper gas pipe diameters.
PIPE LENGTH
[FEET]
SCHEDULE 40 PIPE
INSIDE DIA.
TUBING, TYPE L
OUTSIDE DIAMETER
NAT.
L.P.
NAT.
L.P.
0-10
1/2" [1.3 cm]
3/8" [1.0 cm]
1/2" [1.3 cm]
3 /8" [1.0 cm]
10-40
1/2" [1.3 cm]
1/2" [1.3 cm]
5/8" [1.6 cm]
1 /2" [1.3 cm]
40-100
1/2" [1.3 cm]
1/2" [1.3 cm]
3/4" [2.0 cm]
1 /2" [1.3 cm]
100-150
3/4" [2.0 cm]
1/2" [1.3 cm]
7/8" [2.3 cm]
5 /8" [1.6 cm]
150-200
3/4" [2.0 cm]
1/2" [1.3 cm]
7/8" [2.3 cm]
3 /4" [2.0 cm]
NOTE: Some areas allow copper tubing or galvanized pipe - check with local approval agencies and codes NEVER use plastic
pipe.
Figure 3-30 Gas Line Inlet Location
GAS SUPPLY INLET
THIS SIDE
19 7/8"
ELECTRICAL
SUPPLY INLET
THIS SIDE
29"
36 9/16"
14 9/16"
28 9/16"
LIFTING
HANDLE
MASTER
SWTICH
DETAIL A
DC BACKUP
POWER CORD
EXIT
29 13/16" FLOOR
TO VENT STARTER TOP
SYNC
SWITCH
5"
6 3/4"
32 5/8"
INNER GUIDE WIDTH
23 1/8"
INNER GUIDE
HEIGHT
11"
8 1/16"
HEAT TRANSFER
DUCT KNOCKOUT
40-5/8"
MIN. ROUGH FRAMING WIDTH
11 5/16"
4"X6" COAXIAL
STARTER COLLAR
A
110VAC
INLET
HOT, NO SWITCH
36-3/4"
MIN.
ROUGH
FRAMING
HEIGHT
7"
GAS SUPPLY
INLET 1/2" FNPT