EXTERIOR VENT LOCATIONS AND RESTRICTIONS
ALL MEASUREMENTS FROM CENTERLINE OF VENT CAP
-
Vent Terminal
-
Air Supply Inlet
-
Area where terminal is
not permitted
A =
Clearance above grade, veranda, porch, deck, or
balcony (*12 inches (30 cm) minimum). Vinyl sur-
faces require 24” min.
H =
*Not to be installed above a meter/regulator assembly
within 3 feet (90 cm) horizontally from the center-line
of the regulator
B =
Clearance to window or door that may be opened
(*12 inches (30 cm) minimum.
I =
*Clearance to service regulator vent outlet *3 feet (92
cm) minimum.
C =
*Clearance to permanently closed window (mini-
mum 12 inches (30 cm) recommended to prevent
condensation on window)
J =
*Clearance to non-mechanical air supply inlet to build-
ing or the combustion air inlet to any other appliance.
12 inches (30 cm) minimum.
D =
*Vertical clearance to ventilated soffit located
above the terminal from the center-line of the ter-
minal 24” (60 cm) min.
K =
*Clearance to a mechanical air supply inlet 6 feet (1.8
m) minimum
E =
*Clearance to unventilated soffit 24” min (60 cm)
min.
L =
†
Clearance above paved side-walk or a paved
driveway located on public property (*7 feet (2.1 m)
minimum)
F =
Clearance to outside corner - 7 inches (18 cm).
M =
Clearance under veranda, porch, deck, or balcony
(*12 inches (30 cm) minimum
‡
)
G =
Clearance to inside corner - 12 inches (30 cm).
Vinyl surfaces require 24” min (60 cm).
N=
Minimum 24” horizontal clearance to any surface,
such as an exterior surface, for vertical terminations.
†
A vent shall not terminate directly above a sidewalk or paved driveway, which is located between two single-
family
dwellings and serves both dwellings.
‡
Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
* As specified in CGA B1:19 Installation Codes (1991).
Note
: Local codes or regulations may require different
clearances.
Exterior Vent