51
MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM
As a part of Mendota's on-going program of customer satisfaction, this Form verifies proper installation and operation. It is
important as a reference for future service. It insures long life and trouble-free operation of Mendota fireplaces & stoves
and qualifies the owner for Mendota's lifetime limited warranty. Owner should sign Form when completed and mail a copy
along with Warranty Registration to Mendota. OPTIONALLY, PLEASE REGISTER AT OUR WEBSITE AT:
WWW.JOHNSONGAS.COM/MENDOTA-REGISTRATION.ASP
HOME OWNER: ____________________________
DEALER: _____________________________
ADDRESS: ________________________________
ADDRESS: ____________________________
CITY/STATE/ZIP: ___________________________
CITY/STATE/ZIP: _______________________
SIGNATURE: ______________________________
PHONE: ______________________________
MODEL #: DXV-45 __________________ SERIAL #: ________________________________
DATE INSTALLED: _____ ___________________
Mendota direct vent fireplaces are sophisticated, hi-tech gas appliances. All installation and operating instructions must be
carefully followed. The DXV fireplace must be installed and serviced by a qualified Mendota approved service person.
REF:
MENDOTA DXV45 DT4 INSTALLATION MANUAL
APPROVED VENT PIPES AND VENT CAP INSTALLED - Per Manual.
Vent pipes must be fully twist-locked and leak proof.
Check minimum and maximum vertical / horizontal and vent runs.
CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES & VENT LOCATIONS - Per Manual
INSTALL PROPER SIZE GAS LINES - CHECK FOR GAS LEAKS - Per Manual
CHECK FOR CORRECT GAS PRESSURE AT MANIFOLD - Per Manual
a. 3.5 Inches Water Column Maximum - Nat. Gas
(1/8” WC variation is allowed)
b. 10.0 Inches Water Column Maximum - L.P. Gas
(1/8” WC variation is allowed)
CYCLE BURNERS ON/OFF FOR PROMPT IGNITION - Per "LIGHTING INSTRUCTIONS"
Burner must light IMMEDIATELY - Flame must travel promptly around "curve" & light burner
.
INSTALL LOGS AND ADJUST FLAME - Per Manual
Proper pilot flame impingement on flame sensor & burner - Air shutter opening: 1/16" - 1/8" Nat. Gas - 1/4" LP
Check that flame is "stable" and is not "lifting" off burner
BRIEF OWNER ON OPERATION AND MAINTENANCE OF UNIT
Light Pilot
Operate Burner
Explain blower "delay" operation
WARRANTY REGISTRATION
Your Name ________________________________________________________________
Address ___________________________________________________________________
City _____________________________________ State ____ Zip ____________________
Dealer (Place of Purchase) ___________________________________________________
City _____________________________________ State ____ Zip ____________________
Date of Purchase ___________________ Serial Number ___________________________
Purchaser's Signature _______________________________________________________
MENDOTA DXV-45DT4 DIRECT VENT FIREPLACE
CUT OUT PAGE AND MAIL TO: JOHNSON GAS APPLIANCE CO., 520 E AVE. N.W., CEDAR RAPIDS, IOWA 52405
PLEASE REGISTER AT OUR WEBSITE AT: WWW.JOHNSONGAS.COM/MENDOTA-REGISTRATION.ASP