25
HEARTH PAD SURFACE MUST BE
FLUSH WITH FIREPLACE BOTTOM
HEARTH PAD
SURFACE
Hearth Protection Pad Installation Information when planning to Install the Andover or Prairie
Fronts
Any hearth protection pad installed in front of the DXV-45 Fireplace
must be designed, built and installed so that the hearth protection
pad’s top surface is flush with the bottom-most surface of the
DXV45 Fireplace. See the diagram to the right.
Information specific to the installation of Millennia
Flat Grills, Victoria Filigrees and Tuscany Filigrees
The Millennia Flat Grills, Victoria Filigree and Tuscany Filigree are
designed to be “inside-fit” trim kits. All of these trim kits fit within
the inner perimeter of the Fireplace’s Faceplate and remain flush
within the Faceplate’s front surface, see Figure below. This fitting
method allows flexibility in covering the black visible surface of the
Faceplate with non-combustible materials such as Tile, Mar-
ble, Slate, Stone and Brick; as long as enough room is al-
lowed for the removal of these Mendota Designer Fronts and
the glass door for servicing,
WARNING: COMBUSTIBLE MATERIALS
MUST NOT COVER THE FRONT
SURFACE OF THE FIREPLACE’S
FACEPLATE.