5 of 32
BUILD IN DIMENSIONS
STOVE PERFORMANCE & TESTING
H
W
D
Building in Dimensions
Height
Width
Depth
CHRISTON 550
570 mm
570 mm
380 mm
CHRISTON 750
570 mm
770 mm
380 mm
Log Length
Wood Reload
Interval
Wood Reload
Weight
Max Length
SE Dimensions L x W x D
Number of Logs
CHRISTON 550
40 cm
25 x 11 x 11 cm
1
45 min
1.0 kg
CHRISTON 750
60 cm
25 x 14 x 11 cm
2
50 min
1.6kg
Nominal
Heat Output
Efficiency
CO @
13% O₂
Dust
mg/m₀ ³
DEFRA Smoke
Exempt
Mechanical SE
Air Stop
Secondary Air SE
Requirements
CHRISTON 550
4.8 kW
77.8 %
0.09
30
Yes / SE model
NO
N/A
CHRISTON 750
8.7 kW
78.4 %
0.09
32
Yes / SE model
YES
50 % / 2.5 cm
Christon 550 and 750 models are tested in accordance with EN 13240/13229. The Christon 550 & 750 have been
recommended as suitable for use in smoke control areas when burning wood logs and when fi�ed with a mechanical stop
to prevent closure of the secondary/ter�ary air control. Christon 550 0 cm / 0% and Christon 750 2.5 cm or 50% open
If you are installing an inset stove without u�lising the closed combus�on capabili�es of the Christon wood
burners, you will need to remove the Direct Air Inlet at the rear of the stove to ensure that there is sufficient
air flow to accommodate the requirements of the appliance.