2
Clearance to Combustible Materials
Combustible Material
is wood, dry wall, siding or any other material that has to ability to catch fire.
Built-in structures constructed of wood or other combustible materials may require the use of the OPTIONAL Built-In
Heat Shield Kit to maintain the required clearance to combustible materials. The grill may be supported by either the
three support brackets, or the four leveling feet. Please note that there must be at least 3/8” (1.0 cm) clearance
between the bottom of the grill and the structures.
DIMENSIONS
A 18”
[45.8
cm]
B
3/8” [1.0 cm]
C
2” [5.1 cm]
D
3 1/2” [8.9 cm]
F 30”
[76.2
cm]
E*
1/8” [0.5 cm]
Power Cable Loca on
Built
‐
in Bracket
*NOTE: Clearance dimension E may only be used when the
optional heat shield kit (VGBHSK) has been installed. This
distance is from the outside of the installed heat shield kit.